ARITERM GSM A2
ARITERM SWEDEN AB
Installation instructions -
2011.11.24 - Page 5/8
Input 1 (Ing1 - COM): Alarm or status changes
Alarm relay from the burner to the stove. (grey-brown)
When the burner or stove is started SMS
Started1(Msg100)
is sent.
When the burner or stove is stopped SMS
Stopped1(Msg101)
is sent.
When the burner or stove stops during operational stoppage SMS
Alarm1(Msg102)
is sent.
Input 2 (Ing2 - COM): Smoke gas alarm
5358 Smoke gas sensor.
Settable temperature limit (Tmp2). Factory setting 240˚, setting range 20-300˚.
If the temperature is above the temperature limit for longer than 10 minutes, SMS
Flue gas Alarm (Msg103)
is sent.
To modify the temperature limit:
Send:
Temp??
As a response you get: Temp**1,+053, *2,+240, *3,+053, *4,+050, *5,+053, *
Example: We wish to change the temperature limit to +180 degrees.
Send:
Temp!*2,+180,*
(no spaces)
As a response you get: Temp**1,+053, *2,
+180
, *3,+053, *4,+050, *5,+053, *
Input 3 (Ing3 - COM): Level alarm pellet store
Level alarm fuel. 1350 Capacitive sensor.
If the pellets are missing for more than 10 sec. SMS
Storage Alarm (Msg107)
is sent.
Input 4 (Ing4 - COM): Temperature alarm
5292 Tank sensor.
Settable temperature limit (Tmp4). Factory setting 50˚, setting range 10-90˚.
Sends SMS
TempAlarm (Msg108)
if the temperature has fallen below the temperature
limit (Tmp4) for more than 5 mins.
At first start: The function is deactivated until the temperature rises above the
temperature limit.
To modify the temperature limit:
Send:
Temp?
?
As a response you get: Temp**1,+053, *2,+240, *3,+053, *4,+050, *5,+053, *
Example: We wish to change the temperature limit to +80 degrees
Send:
Temp!*4,+080,*
(no spaces)
As a response you get: Temp**1,+053, *2,+240, *3,+053, *4,
+080
, *5,+053, *
Relay 1 (REL-1)
Remote input burner or stove (red-black)
Operate with SMS:
Remote
Relay 1 draws for 5 secs.
Relay 2 (REL-2)
Remote input burner or stove (red-black
Operate with SMS:
Remote2
Relay 2 draws for 5 secs.
To check the system send SMS
Status?
Response:
Status Ariterm:
Supply 12.30 volt
GSM signal: 4
Temp.Internal +061
Temp. Flue gas +250
Alarm1 (Msg102) Alarm2 (Msg106)
Other
The unit remembers the last status after the power cut
Technical data
Dimensions
105 x 80 x 30 mm
Voltage
10 - 28 VDC
Current consumption
Standby approx 20 mA
Inputs
4 alarm zones NO or NC or temperatures
Outputs
2 Closing relay outputs 1A 24V AC/DC
Temperature measurements Internally in the unit, can be supplemented
with temperature sensors on inputs 1 - 4
Temperature range
-20 to +55 degrees C
Send SMS
Ariterm!!01
at following connection: