Installation example: please refer to example of Bionet with solar heating tank
1. Boiler
2. Expansion card
3. Boiler sensor
4. Tank sensor
5. Bivalent shunt
6. Hot water tube sensor
7. Outdoor sensor
7b. Room sensor
8. Charge pump
9. Radiator pump
10. Safety vent
11. Air vent
12. Manometer
13. Expansion tank
14. Accumulator tank
2
BIONET
Exp.
kärl
Rad.-system
Till solfångar
er
Förvärmning
1
2
1
3
7
8
4
6
5
13
10
11
9
14
11
12
vv
kv
kv
7b
Hot tap water
Bionet does not have an in-built function for hot
water through the taps. Hot water is produced for
example through a separate solar heating tank or
equivalent (please refer to relevant drawing).
Note!
Before starting any work on the boiler please
switch the mains power to the boiler off to ensure
that no electrical current runs through it. All work
on the boiler must be carried out by a qualifi ed
electrician.
ARITERM SWEDEN AB
Installation, Operation and Maintenance - 2007.10.26- 5/12
INSTALLATION