Keypad Installation

Wiring Specifications

Connect the additional keypads either using a STAR or MULTIDROP configuration.

MULTIDROP

the keypads are 'daisy chained' together, each keypad being connected in parallel

to the one before it.

STAR

each keypad is wired back separately to the control panel terminals.

Any combination of the above wiring methods is allowed with the restriction that the total cable length

on each of the wiring loops (either multidrop or star) is restricted to 100m.

The following diagram shows how 4 RKPs may be connected using both methods.

1

2

3

4

ON SD

MIN MAX

D

C

B

A

15

14 

13

12

SW1

CD3008

Control panel

Terminal 5

1

2

3

4

ON 

ON 

OFF

OFF

1

2

3

4

Keypad 1

(all off)

Keypad 2

1

2

3

4

1

2

3

4

Keypad 3

Keypad 4

Figure 3.

Figure 4.

Figure 5.

Содержание CS350

Страница 1: ...ains installation details for the CS350 control panels It provides the basic programming and instal lation information required by technicians and engineers CS350 Installation Instructions Downloaded from http www guardianalarms net ...

Страница 2: ...14 1791 999 2 ...

Страница 3: ...s and has the following features l Facility for up to 4 CD3008 remote keypads one CD3008 is supplied with the panel l 6 freely programmable dual zones l Auxiliary tamper input l Supervised bell tamper input l Digital communicator fault input reprogrammable to include remote engineer reset l New perimeter system capability which provides local alarms for perimeter zone activations This can reduce f...

Страница 4: ...K CABLE ENTRY FROM BOTTOM MOUNTING HOLE MOUNTING HOLE MOUNTING HOLE DIPSWITCHES FOR KEYPAD ID SPARE SCREW TO FIX COVER ONTO BASE ADJUSTMENT DISPLAY CONTRAST CD3008 PUSH CLAMP GENTLY TO REMOVE PCB CD3008 LIFT REMOVE SCREW IF FITTED PUSH PUSH IN CLIP WITH SCREW DRIVER AND LIFT UP LID 1 2 3 Figure 1 Figure 2 ...

Страница 5: ...ely to the control panel terminals Any combination of the above wiring methods is allowed with the restriction that the total cable length on each of the wiring loops either multidrop or star is restricted to 100m The following diagram shows how 4 RKPs may be connected using both methods 1 2 3 4 ON SD MIN MAX D C B A 15 14 13 12 SW1 CD3008 Control panel Terminal 5 1 2 3 4 ON ON OFF OFF 1 2 3 4 Key...

Страница 6: ...e select prompt when switched on for the first time UK IRL Press é 1 Enter é and 1 to select English language Note that this also happens after returning to factory default See page 21 for more details 6 EntertheDefaultUserSecurityCode 1 1 2 2 atthekeypadtodisarmthesystem Thekeypad display shows DISARMING and the audibles if sounding will stop Display then shows any zones which are open and caused...

Страница 7: ... block enter programming option confirm changes accept option X quit programming block quit programming option reject changes After have installed the additional keypads mind the correct dipswitch ID setting go to the Engineer Programming Mode and proceed as follows 1 Use the ê key till OUTPUTS REMOTES is displayed then enter ü 2 Use the ê key till INSTALL REMOTE is displayed then enter ü 3 The di...

Страница 8: ...ll Bells Cut ON OFF TIMERS Dig Cutout ON OFF Perim Bell Cutout nn Timers Menu 5 Time hh mm Time hh mm 6 Date dd mm yy Date dd mm yy 7 Summertime Forward Date Backward Date Summertime ON OFF Main Menu Timers Menu 3 1 Change Codes xx Code In Use xx Code Unused New Code Verify Error 2 Code Privilege 01 Fs Us OK USER ATTRIBUTES 02 OK 03 OK Mn Manager 04 OK In Inhibit USERS Leave this Ps Part Set Us Un...

Страница 9: ...ck 4 Zone Name La Local Alarm Contact In Inhibit 5 Loop Type Alarm 24 24 hours Loop Type Dual Pg Partguard So Soak Test Ac Access Ch Chime KEY ZONE ATTRIBUTES Fs Full Set Ps Part Set Us Unset Pu Pulsed Main Menu Qs Quick Set 5 1 Output Type 01 Disarm Arm OUTPUT TYPES 0x 06 Disarm Arm Alarm P A Fire Tamper OUTPUTS 2 Install Remote Remote kk Latch REMOTES Fire Detect Reset k CD3008 Buzzer Int Bell E...

Страница 10: ... ON OFF Access EE Access Partgd Digi ON OFF Latched Chime ON OFF Int Bell Chime ON OFF Miscellaneous Menu 4 Eng Reset Menu Reset Code FTC or Code Only P A Reset ON OFF Tamper Reset ON OFF MISCELLANEOUS Alarm Reset ON OFF Clear Engineer Reset Miscellaneous Menu 5 Warnings PF Buzzer ON OFF LF Buzzer ON OFF Miscellaneous Menu 6 Factory Prog Menu Engineer Lock ON OFF Miscellaneous Menu 7 Change Langua...

Страница 11: ...d LED s 2 TIMERS 2 1 Entry Time Programmable between 0 to 99 seconds 2 2 Exit Time Programmable between 0 to 99 seconds 2 3 Split Entry Time When this option is set and the entry time is exceeded then only the interior bells will sound Only after the additional entry time expired which is half the time programmed in 2 1 will a full alarm be created 2 4 Bell Times 2 4 1 Bell Cutout Programmable bet...

Страница 12: ...th 1 hour start of summer time 2 7 2 Backward date Date at which clock is returned with 1 hour start of wintertime 2 7 3 Summertime ON OFF Select for ON if automatic correction to summertime is required 3 Users 3 1 Change Codes Programme here user code 01 to 04 Use from 4 up to 6 digits with the exception of 0 Deleting a code is achieved by entering ü after appearance of New code _ Code 4 can be u...

Страница 13: ...put is not operational Tamper Input is 24Hrs operational Activation of input causes internal bell alarm in disarmed state and full alarm in armed state The input is automatically bypassed after an alarm till the second valid entry of a user code output tamper alarm int bell ext bell systemclear fire reset P A Input is 24Hrs operational Silent or audible Personal Attack alarm is determined in funct...

Страница 14: ...ps and system arms 4 seconds after Terminator closing the input 4 2 Zone Attributes Attributes define the operation of the zone type Some types have attributes inherent to them Others can not be changed which will be displayed by No Option ATTRIBUTE FUNCTION In Allows inhibiting of alarm and exit entry zones 24 Creates a 24Hrs zone Only applicable for Alarm types Pg Partguard Zone is inhibited dur...

Страница 15: ...Define here the typical function of each output 1 to 6 TYPE FUNCTION Disarm Arm Reflects the control panel s arm disarm status Alarm Switches with intrusion and tamper alarm Tamper only when armed PA Switches with PA alarm and or Duress alarm Fire Switches with a fire alarm Tamper Switches with a 24Hrs and or a tamper alarm Latch Switches after exit time and or walk test Resets with disarm or star...

Страница 16: ...me a zone is closed 6 1 2 Forced Arm Opts Determine here the forced arming conditions Input s and code s must have the In attribute to be able to force arming of the panel Forced arming can be achieved in three ways a Go to the Forced Arm menu in the user mode and accept b Arm the panel and enter éé when the display shows Open Zone s c Arm the panel with a keyswitch while a forced arm option has b...

Страница 17: ...nel is armed with or without exit time 6 3 2 Access zones with Partguard Define if an access zone becomes an entry exit zone when partially armed or not 6 3 3 Partguard Digi On Off Define if the alarm output operates when partially armed or not 6 3 4 Latched Chime On Off If Latched Chime is set to On the chime will remain operational each timethesystemisdisarmeduntillmanuallycanceledbyuser 6 3 5 I...

Страница 18: ... Lock Define if an engineer code is required to factory default the panel See also the chapter returning to factory default 6 7 Change Language Change the language used by the panel to Dutch French or Italian 6 8 System Clear Inputs Define the parameters which will determine the function of the System Clear output 6 8 1 System Clear Mains On Off Will a 230V mains failure switch the output off or n...

Страница 19: ...ut will merely set Perimeter Alarm digi output l The output functionality is fixed both bells go for the Perimeter Time when a Perimeter Alarm happens Typical Application Example WIRING PROGRAMMING OPERATION Inertia Activation Perimeter Alarm Full Alarm Perimeter Alarm Perimeter Alarm For programming see Programming Map Zones è Zone attributes Ls for Shock Zone 1 4 La for Contacts Zone 1 6 Timers ...

Страница 20: ... next name ê or return to the previous menu section X Literal text is available for programming customized zone and user names The keypad digits each represent a set of characters KEYPAD CHARACTER SET HOW TO PROGRAM NAMES Function keys used ê key Move to next character é key Move to previous character 4 key Confirm to reprogram current text Confirm changes to the description shown on the display a...

Страница 21: ...plug on link and reconnect the battery With Engineer Lock programmed 1 Enter Engineer Mode using EXISTING Engineer code at Keypad 1 2 Select Factory Prorgram Menu from the miscellaneous section and scroll down to Default Settings Enter accept NOTE When the existing engineer code is unknown then the control panel must be returned to the factory for reprogramming The panel always powers up in Armed ...

Страница 22: ...M devices are wired as normal and a 4K7 resistor is fitted in PARALLEL with the complete loop 2 The TAMPER switches devices are wired as normal and a 4K7 resistor is fitted in series with this loop Principles of Dual Operation All devices closed loop resistance is 4K7 TAMPER device open loop is open circuit ALARM device open loop resistance is 9K4 ie EOL resistor PLUS parallel resistor Example 1 F...

Страница 23: ...LD OFF VOLTAGE TAMPER LOOP SPEAKER BEACON CONTACTS TAMPER SWITCH BATTERY black red Program Internal 5 and External 7 Bell outputs for positive trigger JUMPERS CUT OFF TIMER minutes 3 5 10 20 J1 J2 cut link 3 2 5 7 1 2 3 4 5 6 7 8 9 10 4K7 AS290 AS390 16 17 Wiring of Aritech Sirens Figure 9 ...

Страница 24: ...tputs Principle of operation from outputs Output as shown is High When programmed for trigger the output will switch to with an alarm condition Wiring to Digital Communicator Figure 10 Figure 12 Figure 11 Wiring of Fire Detectors ...

Страница 25: ...l 24 3 Buzzer option line fault 65 2 Buzzer option power failure 65 1 C Change of hour backward 27 2 Change of hour forward 27 1 Chime option latched 63 4 Chime internal bell on 63 5 D Date program curren 26 DD MM YY E Engineer code program 33 Engineer lock select 66 2 Engineer reset clear 64 5 Engineer reset PA 64 2 Engineer reset tamper 64 3 Engineer reset Alarm 64 4 Entry time program 21 SS Exi...

Страница 26: ...arming OFF Inputs alarm or ALARM dual Keyswitch PULSED option KEY PA at keypad OFF PA with line fault BELLS bells or silent PA activations BELLS bells or silent Partguard OFF acces to E EE Partguard OFF activates digi Partguard INSTANT time instant Auto rearm NEVER option x Not Available for attributes and privileges charts l Default ZONE TYPES No Default Required 1 Exit Entry 2 Alarm 3 Alarm 4 Al...

Страница 27: ...is proves that the panel is functioning correctly 4 Check the zone wiring to ensure that the circuit is closed and that there are no shorts on the cables Reconnect the wires back to the panel and retest Control panel activates 1 Check that the battery is connected correctly during a short power 2 Check that the battery fuse is not blown failure 3 Ensure that the battery is fully charged and is lar...

Страница 28: ...ating inserting a higher value fuse may damage the panel Spread the load of the bells across the bell outputs or fit a relay and use the auxiliary power output to provide some of the current Ensure that the operator is not entering the duress code when switching off the system This happens when the keypad is not receiving correct data from the panel Check wiring to the keypad especially for swappe...

Страница 29: ... mA each Outputs Loop 6 inputs configurable as double pole loops using 4K7 resistors characteristics Response time 300 ms Battery 12 V lead acid rechargeable battery not supplied Backup Float charging method at 13 8 V 5 800mA max charging current 6 5 Ah recommmended Auxiliary Power 13 8 V DC fused at 800mA Output Note if the combined current is greater than 800mA for the above devices the load wil...

Страница 30: ...14 1791 999 30 CS350 WIRING DIAGRAM Figure 13 N C N C N C N C N C N C FACTORY SETTINGS 1 2 3 4 A B C D E O L ...

Страница 31: ...14 1791 999 31 ...

Страница 32: ...14 1791 999 32 Aritech reserves the right to change specifications without notice 4 Aritech is an ISO 9001 certified manufacturer ...

Отзывы: