Problem Solving
Check that the 'In' attribute is set for this zone number
('Zone Attribute' in 'Zones' menu). Check that the user code has 'In' privilege
('Code Privileges' in 'Users' menu).
Check that there is no short circuit in bell wiring.
Disconnect bell wires from terminal and, observing correct polarity, connect
across battery. If bells ring, wiring is correct. The load of the bells is greater
than the fuse rating, inserting a higher value fuse may damage the panel.
Spread the load of the bells across the bell outputs or fit a relay and use the
auxiliary power output to provide some of the current.
Ensure that the operator is not entering the duress code when switching off
the system.
This happens when the keypad is not receiving correct data from the panel.
Check wiring to the keypad, especially for swapped wires.
Check that the address is correctly set on the keypad.
Alarm zones cannot
be inhibited.
Bell fuse blows when
bells are sounding.
PA is activating when
alarm is switched off.
'No panel data' shows
on the display.