INSTALLATION

TECHNICAL INFORMATION FOR THE INSTALLER

• 

Use protective gloves for handling, preparing, and installing the product.

• 

This product can be embedded in a worktop 20

 ÷ 60 mm thick.

• 

If there is no oven beneath the hob, insert a separator panel with a surface at least equal to the opening in the work surface. This panel must be 
positioned at a maximum distance of 150 mm below the upper surface of the work surface but, in no case, less than 70 mm from the bottom of the 
hob. If you intend to install an oven beneath the hob, make sure that it is equipped with a cooling system.

• 

Where the rating plate is obscured by cabinetry when the cooktop is in the installed position, place the duplicate rating plate (provided together with 
the literature) on a surface of the cabinetry adjacent to the cooktop.

NOTE: An 

may extinguish the burner 

if the removable panel is not installed. The air 

may occur when you open or close the 

cabinet door or drawer.

• 

An authorized person must install this appliance in accordance with this instruction manual:
• 

AS/NZS 5601.1 - Gas installations (installation and pipe sizing)

• 
• 

Local electrical regulations

• 

Building Code of Australia and any other government authority.

DIMENSIONS AND DISTANCES TO BE MAINTAINED

A

If that horizontal clearance is less than 200 mm, that vertical surface must be protected by a non combustible material for 
150 mm above the cooktop surface across the entire length (depth, width).
The shown area indicates the protected surface, which may be ceramic tiles or other approved material.

The high from the worktop surface to the top of the pan support is 51 mm.

CAUTION:
The installer shall test the appliance before leaving. Test the safety operation of the ignition system on all burners individually and combined.

Pan support

Worktop surface

51 mm 

The appliance belongs to class 3 and is therefore subject to al l the provisions established by the provisions governing such appliances.

Mod.: GGA24BKAUS

Mod.: GGA34BKAUS

Ventilation  must  be  in  accordance  with  AS/NZS  5601  -  Gas  Installation.  In  general,  the  appliance  should  have  adequate  ventilation  for 

uitable for 

this temperature.

NOTE: In case of installation of a hood above the cooktop please refer to the range hood instructions for the correct distance. Clearance A, 
between the highest part of the highest burner of the gas cooking appliance and a range hood or exhaust fan (overhead clearance), shall be no 
less than 600 mm for a range hood, and no less than 750 mm for an exhaust fan. 

The minimum clearance from a combustible surface shall be 

a 200 mm horizontal distance from the periphery of any gas burner (AS/NZS 5601.1).     

94

110

87

87

74

90

Содержание GGA24BKAUS

Страница 1: ...physical supervised or have been given instructions on safe use and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be carried out by c...

Страница 2: ...e in turning the burner s knobs please contact After Sales Service for replacement of the burner tap if found to be faulty The openings used for the ventilation and dispersion of heat must never be co...

Страница 3: ...SAL OF PACKAGING MATERIALS The packaging material is 100 recyclable and is marked with the recycle symbol The various parts of the packaging must therefore be disposed of responsibly and in full compl...

Страница 4: ...S TO BE MAINTAINED A If thathorizontalclearanceis less than 200 mm that verticalsurfacemust be protectedby a noncombustiblematerialfor 150 mm above the cooktop surface across the entire length depth w...

Страница 5: ...e temperatures Ensure that the supply connection point is accessible with the appliance installed To facilitate the shield may need to be removable The cooktop has a special seal which prevents liquid...

Страница 6: ...d underneath or next to the hot plate The hose should not be subjected to abrasion kinking or permanent deformation and should be able connections tested for gas leaks Natural Gas Natural Gas installa...

Страница 7: ...nce with the provisions and standards in force Before connecting the appliance check that The voltage matches the value shown on the rating plate and the section of the wires of the electrical system...

Страница 8: ...ec If after that time has elapsed the burner does not remain lit wait at least one minute before trying to light it again NOTE should particular local conditions of the delivered gas make The burner m...

Страница 9: ...re indicated in the Instruction technician injector not supplied with the appliance must be ordered from After Sales Service adjust the minimum setting of the taps NOTE when liquid petroleum gas is us...

Страница 10: ...of gas required It is advisable to tighten the injector in place Aftertheinjectorshavebeenreplaced theburnersmustberegulated as explained in ADJUSTING MINIMUM GAS SETTING OFTAPS The technician must re...

Страница 11: ...provided you ensure All spillages are cleaned up as soon as they occur Burner are kept clean Burner ports are free of debris food or anything else that may cause an obstruction Electrode and thermoco...

Страница 12: ...XXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX the serial number number after the word SN on the rating plate located under the appliance The serial number is also...

Отзывы: