NATURAL GAS TO UNIVERSAL LP GAS CONVERSION PROCEDURE

Appliance models: Gas vitroceramic cooktop models:

 

 

60 cm.   

 

4 Burners

 

 

90 cm.   

 

5 Burners

1.  Remove each burner cap and burner skirt.
2.  Remove the Natural Gas main injector with a 7 mm/VF tube spanner 

and replace with the appropriate size Universal LP Gas main injector 
for each burner. The following injector sizes are required for Universal
LP Gas:

Burner   

 

Main injector

Ultra rapid 

1.00 B mm

Rapid 

0.91 mm

Semi Rapid Reduced 

0.60 mm

Semi Rapid 

0.70 mm

Auxiliary 

0.53 mm

Fig. 6

WOK ADAPTER

 

Use the WOK adapter (included) only on the ultra rapid burner. 
WOK PAN is not included.

Fig. 7/A

Fig. 7/B

3.  Remove the control knob, with a thin shaft blade screwdriver down 

the  centre  of  each  gas  valve  shaft.  screw  the  by-pass  injector  fully 
clockwise.

5.  Disconnect gas inlet pipe from the Natural Gas Regulator.
6.  Remove the Natural Gas Regulator from the appliance.

conversion kit.

10.  Adjust the gas pressure to 2.75 kPa.

is  not  stable  on  the  simmer  setting,  adjust  the  by-pass  screw,  until 

12.  If not already removed, remove the "Only for use with Natural Gas" 

label adhered to the bottom panel near the gas connection.

13.  Fit the new data label included in the gas conversion kit.

REPLACING  THE  INJECTORS  (see  the  injector  table  in  the  Safety 
instructions)

REPLACING THE INJECTORS

injectors suited to the type of gas required.

B

".

Now unscrew injector "

A

the type of gas required.
It is advisable to tighten the injector in place.

After the injectors have been replaced, the burners must be regulated 
as explained in ADJUSTING MINIMUM GAS SETTING OFTAPS.
The  technician  must  reset  any  seals  on  the  regulating  or 

gas regulation on the appliance instead of the already existing one.
This label is supplied in the packet containing the spare injectors.
The envelope with the injectors and the labels can be included in the 
kit, or at disposal to the authorised Customer Care Department.

For the sake of convenience, the injector table also lists the heat inputs of 
the burners, the diameter of the injectors and the working pressures of 
the various types of gas.

supplied  with  the  injectors  in  such  a  way  that  it  covers  the  existing 
information relating to gas calibration.

Note: ensure to remove the natural gas regulator device and replace 
it with the propane I LPG test point adaptor.

ADJUSTING MINIMUM GAS SETTING OF TAPS

The  adjustment  must  be  performed  with  the  tap  in  a  minimum  gas 

The primary air of the burners does not need to be adjusted.

• 

on to its rod. The bypass for minimal rate regulation can be: beside the 

can be done trought the insertion of a small screwdriver "D" beside 

adequately regulated to the "Reduced rate" position.

continuous and steady. Reassemble the several components.

It is understood that only burners operating with Natural gas should 
be subjected to the above mentioned adjustments.
The screw must be fully locked when the burners operate with Liquid 
gas.

Upon  completion  of  adjustment,  reseal  using  sealing  wax  or  an 
equivalent material. 

Содержание GGA24BKAUS

Страница 1: ...physical supervised or have been given instructions on safe use and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be carried out by c...

Страница 2: ...e in turning the burner s knobs please contact After Sales Service for replacement of the burner tap if found to be faulty The openings used for the ventilation and dispersion of heat must never be co...

Страница 3: ...SAL OF PACKAGING MATERIALS The packaging material is 100 recyclable and is marked with the recycle symbol The various parts of the packaging must therefore be disposed of responsibly and in full compl...

Страница 4: ...S TO BE MAINTAINED A If thathorizontalclearanceis less than 200 mm that verticalsurfacemust be protectedby a noncombustiblematerialfor 150 mm above the cooktop surface across the entire length depth w...

Страница 5: ...e temperatures Ensure that the supply connection point is accessible with the appliance installed To facilitate the shield may need to be removable The cooktop has a special seal which prevents liquid...

Страница 6: ...d underneath or next to the hot plate The hose should not be subjected to abrasion kinking or permanent deformation and should be able connections tested for gas leaks Natural Gas Natural Gas installa...

Страница 7: ...nce with the provisions and standards in force Before connecting the appliance check that The voltage matches the value shown on the rating plate and the section of the wires of the electrical system...

Страница 8: ...ec If after that time has elapsed the burner does not remain lit wait at least one minute before trying to light it again NOTE should particular local conditions of the delivered gas make The burner m...

Страница 9: ...re indicated in the Instruction technician injector not supplied with the appliance must be ordered from After Sales Service adjust the minimum setting of the taps NOTE when liquid petroleum gas is us...

Страница 10: ...of gas required It is advisable to tighten the injector in place Aftertheinjectorshavebeenreplaced theburnersmustberegulated as explained in ADJUSTING MINIMUM GAS SETTING OFTAPS The technician must re...

Страница 11: ...provided you ensure All spillages are cleaned up as soon as they occur Burner are kept clean Burner ports are free of debris food or anything else that may cause an obstruction Electrode and thermoco...

Страница 12: ...XXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX the serial number number after the word SN on the rating plate located under the appliance The serial number is also...

Отзывы: