Ariston GGA24BKAUS Скачать руководство пользователя страница 3

After connection to the gas supply, check for leaks 

with soapy water. Light up the burners and turn the 
knobs  from  max  position  to  minimum  position  to 

ADAPTING TO DIFFERENT TYPES OF GAS

In  order  to  adapt  the  appliance  to  a  type  of  gas 

other  than  the  type  for  which  it  was  manufactured 
(indicated on the rating plate), follow the dedicated 
steps provided after installation drawings.

ELECTRICAL WARNINGS

IMPORTANT: The data relevant to the voltage and 

power absorptions are indicated on the rating plate.

The power cable must be long enough to connect 

the appliance, once 

in its housing, to the main 

power supply. Do not pull the power supply cable.

It  must  be  possible  to  disconnect  the  appliance 

from  the  power  supply  by  unplugging  it  if  plug  is 
accessible, or by a multi-pole switch installed upstream 
of the socket in accordance with the wiring rules and 
the  appliance  must  be  earthed  in  conformity  with 
national electrical safety standards. 

Do  not  use  extension  leads,  multiple  sockets  or 

adapters.  The  electrical  components  must  not  be 
accessible to the user after installation. Do not use the 
appliance  when  you  are  wet  or  barefoot.  Do  not 
operate this appliance if it has a damaged power cable 
or plug, if it is not working properly, or if it has been 
damaged or dropped.

If the supply cord is damaged, it must be replaced 

with an identical one by the manufacturer, its service 
agent or similarly 

persons in order to avoid a 

hazard - risk of electrical shock.

CLEANING AND MAINTENANCE

WARNING:  Ensure  that  the  appliance  is  switched 

and disconnected from the power supply before 

performing  any  maintenance  operation;  never  use 
steam cleaning equipment - risk of electric shock.

Do not use abrasive or corrosive products, chlorine-

based cleaners or pan scourers.

DISPOSAL OF PACKAGING MATERIALS

The  packaging  material  is  100%  recyclable  and  is  marked  with  the  recycle 
symbol 

 .

The various parts of the packaging must therefore be disposed of responsibly 
and  in  full  compliance  with  local  authority  regulations  governing  waste 
disposal.

DISPOSAL OF HOUSEHOLD APPLIANCES

This  appliance  is  manufactured  with  recyclable  or  reusable  materials. 
Dispose of it in accordance with local waste disposal regulations. For further 
information on the treatment, recovery and recycling of household electrical 
appliances, contact your local authority, the collection service for household 
waste  or  the  store  where  you  purchased  the  appliance.  This  appliance  is 
marked in compliance with European Directive 2012/19/EU, Waste Electrical 
and Electronic Equipment (WEEE). 
By ensuring this product is disposed of correctly, you will help prevent negative 
consequences for the environment and human health.

The  symbol 

  on  the  product  or  on  the  accompanying  documentation 

indicates that it should not be treated as domestic waste but must be taken 
to an appropriate collection center for the recycling of electrical and electronic 
equipment. 

ENERGY SAVING TIPS

Use pots and pans with bottom width equal to that of the cooking zone.

When possible, keep pot lids on during cooking.
Use a pressure cooker to save even more energy and time.
Place the pot in the middle of the cooking zone marked on the hob.

DECLARATION OF CONFORMITY

This  appliance  meets  the  Ecodesign  requirements  set  out  in  European 

INJECTORS TABLE

ELECTRIC SUPPLY: 220-240 V ~ 50-60 Hz    

1

.

1

 W

BURNERS

GAS

NORMAL

PRESSURE

(kPa)

INJECTOR

DIAMETER

(1/100 mm)

NOMINAL

HEAT

INPUT (MJ/h)

MAX.

DESCRIPTION

1

ULTRA RAPID

2.75
1.00

100 B 
175 B 

12.6
14.5

2

RAPID

2.75

1.00

91

155

10.4
12.0

3

SEMIRAPID

REDUCED

2.75

1.00

60

105

4.9
5.4

4

SEMIRAPID

2.75

1.00

70

120

6.3
7.1

5

AUXILIARY

2.75

1.00

53
90

3.6
4.1

U-LPG

U-LPG

U-LPG

NATURAL

NATURAL

U-LPG

NATURAL

U-LPG

NATURAL

NATURAL

EN

Содержание GGA24BKAUS

Страница 1: ...physical supervised or have been given instructions on safe use and understand the hazards involved Children must not play with the appliance Cleaning and user maintenance must not be carried out by c...

Страница 2: ...e in turning the burner s knobs please contact After Sales Service for replacement of the burner tap if found to be faulty The openings used for the ventilation and dispersion of heat must never be co...

Страница 3: ...SAL OF PACKAGING MATERIALS The packaging material is 100 recyclable and is marked with the recycle symbol The various parts of the packaging must therefore be disposed of responsibly and in full compl...

Страница 4: ...S TO BE MAINTAINED A If thathorizontalclearanceis less than 200 mm that verticalsurfacemust be protectedby a noncombustiblematerialfor 150 mm above the cooktop surface across the entire length depth w...

Страница 5: ...e temperatures Ensure that the supply connection point is accessible with the appliance installed To facilitate the shield may need to be removable The cooktop has a special seal which prevents liquid...

Страница 6: ...d underneath or next to the hot plate The hose should not be subjected to abrasion kinking or permanent deformation and should be able connections tested for gas leaks Natural Gas Natural Gas installa...

Страница 7: ...nce with the provisions and standards in force Before connecting the appliance check that The voltage matches the value shown on the rating plate and the section of the wires of the electrical system...

Страница 8: ...ec If after that time has elapsed the burner does not remain lit wait at least one minute before trying to light it again NOTE should particular local conditions of the delivered gas make The burner m...

Страница 9: ...re indicated in the Instruction technician injector not supplied with the appliance must be ordered from After Sales Service adjust the minimum setting of the taps NOTE when liquid petroleum gas is us...

Страница 10: ...of gas required It is advisable to tighten the injector in place Aftertheinjectorshavebeenreplaced theburnersmustberegulated as explained in ADJUSTING MINIMUM GAS SETTING OFTAPS The technician must re...

Страница 11: ...provided you ensure All spillages are cleaned up as soon as they occur Burner are kept clean Burner ports are free of debris food or anything else that may cause an obstruction Electrode and thermoco...

Страница 12: ...XXXXXXXXX XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX the serial number number after the word SN on the rating plate located under the appliance The serial number is also...

Отзывы: