6. settings - adjustment - problem identifi cation parameters
423
Parallel curve shift Zone 1 Offset
from - 14 to + 14 (HT)
0
from -7 to +7 (LT)
To adapt the heating curve to the system requirements, shift the curve in parallel so that the calculated fl ow tempe-
rature is modifi ed, in addition to the room temperature.
Access the parameter and press “+” or “-”
buttons while temperature regulation is activated to shift the curve
upwards or downwards.
Each step represents a fl ow temperature increase/decrease of 1°C in relation to the set-point value.
Warning!
The curves can be shifted upwards or downwards without accessing the parameter, using the “+” or “-”
buttons,
but the display will always show -7 to +7
High temperature - each step 2°C
Low temperature - each step 1°C
425
Maximum Central Heating Temperature
Zone 1
from 35 to 85 °C
(Param. 420 = 1)
82
from 20 to 45 °C
(Param. 420 = 0)
45
426
Minimum Central Heating Temperature Zone
1
from 35 to 85 °C
(Param. 420 = 1)
40
from 20 to 45 °C
(Param. 420 = 0)
25
700
Test Mode
t
-
= Max Heating power
t
--
= Max DHW power
t
--
= Minimum power
Enabled also by pressing for
10 seconds the Reset button.
This function is deactivated
automatically after 10
minutes, or when the RESET
button is pressed.
701
Air purge Function
Press MODE button to active
822
Fan Speed - x100 RPM
831
Flow Heating temperature (°C)
832
Return Heating temperature (°C)
842
D.H.W. Inlet Temperature
Display only with Solar Kit or
external storage Kit
P
a
rameter
Description
value
def
ault
setting