5. boiler protection devices
The boiler is protected from malfunctioning by means of
internal checks performed by the electronic microprocessor
P.C.B., which stops the boiler from operating if necessary.
In the event of the boiler being shut off in this manner, a code
appears on the display which refers to the type of shut-off and
the reason behind it.
There are two types of shut-off:
5.1 Safety shut-off
This type of error is “volatile”, which
means that the boiler starts up
again automatically as soon as the
problem which caused the shut-off
is removed; the error is indicated by
the «
Err
»
(ex.
Err/110
) and the
symbol
which appears on the
display and the error code.
In fact, soon as the cause of the shut-off disappears, the boiler
starts up again and continues to operate normally.
In the event of error
108
-
Shut-off due to insuffi cient water
pressure
inside the heating circuit - the boiler will perform a
safety shut-off.
You can increase the pressure by fi lling the heating circuit.
In this case or if the re-balancing
request is performed on a frequent
basis, switch the boiler off, turn the
external electric switch to the OFF
position, shut off the gas cock and
contact a qualifi
ed technician to
check for any leaks of water.
5.2 Shutdown
This type of error is “non-volatile”, which means that it is not
removed automatically.
On the display fl ash Err and the error
code -
es.
Err/501
, and appear the symbol
.
To restore normal operation press the
button on the
control panel.
5.3 Malfunction warning
This warning is shown by the display in the following format:
5P1
5P1
= FIRST IGNITION ATTEMPT UNSUCCESSFUL
the fi rst fi gure indicating the operational assembly is followed
by a P (warning) and the code relating to the specifi c warning.
Important
If this shutdown occurs frequently, contact an authorised
Technical Service Centre for assistance. For safety reasons,
the boiler will permit a maximum of 5 resets in 15 minutes
(5 presses of the RESET button); at the 6th attempt within
this 15-minute period the boiler will shut down and may
only be operated again after the electricity supply has been
disconnected. If the shutdown is occasional or an isolated
event, this is not a problem.
The fi rst fi gure of the error code (e.g. 1 01) indicates within
which operational assembly the error occurred.
1 - Primary Circuit
2 - Domestic Hot Water Circuit
3 - Internal Electronic Part
4 - External Electronic Part
5 - Ignition and Detection
6 - Air inlet - fl ue gas outlet
7 - Multi-zone Heating
5.4 Table summarising error codes
OK
ESC
D.H.W. circuit Central Heating circuit
1 01
Overheat
1 03
Insuffi cient circulation
1 04
1 05
1 06
1 07
1 08
Insuffi cient water (request fi lling)
1 09
System pressure > 3 bar
1 10
C.H. Flow temp. probe circuit open / short circuit
1 12
C.H. Return temp. probe circuit open / short
circuit
1 14
External sensor circuit open / short circuit
1 16
Floor Thermostat contact open
1 P1
Insuffi cient circulation indication
1 P2
1 P3
D.H.W. circuit
2 05
DHW In Probe Open Circuit - Solar Kit (optional)
Internal P.C.B.’s
3 01
EEPROM error
3 02
Comunication error
3 03
Main P.C.B. error
3 04
Too many (> 5) resets in 15 minutes
3 05
Main P.C.B. error
3 06
Main P.C.B. error
3 07
Main P.C.B. error
Ignition and Detecion
5 01
No fl ame detected
5 02
Flame detected with gas valve closed
5 04
Flame lift
5 P1
1st Ignition Failed
5 P2
2nd Ignition Failed
5 P3
Flame cut-off
Air Inlet / Flue gas outlet
6 10
Overheat (Main heat exchanger)
6 12
Insuffi cient fan speed
Fig. 5.1