60
23. Technical data
Model
SYSTEM A 24
SYSTEM A 30
CE certificate
1312-BP-4083
1312-BP-4084
Performance category
****
****
NoX class
5
5
Category
II2H3P
II2H3P
Heating output
80°C/60°C
kW
7 to 24
9 to 29
Heating output
50°C/30°C
kW
7 to 26
9 to 32
Variable heating power
PN max
kW
24
29
Nominal gas flow rate
(15°C-1013 mbar)
min
max
min
max
Central Heating (gas flow rate)
Qn
kW
7
24
9
29
G20 (NG H - Lacq) 34.02 MJ/m
3
under 20 mbar
Vr
m
3
/h
0.79
2.65
0.99
3.17
G31 (propane) 46.4 MJ/kg under 37 mbar
Vr
kg/h
0.58
1.94
0.73
2.33
Membrane Diameter (mm)/marking
G20
mm
without
without
G31 propane
mm
4.4
4.8
Adjustable heating outlet temperature
°C
25 to 85
25 to 85
Central heating minimum flow rate
l/h
300
300
Central heating circuit maximum pressure
Pw max
bar
3
3
Central heating expansion vessel capacity
L
6
8
Expansion vessel inflation pressure
bar
0.7
0.7
Electric voltage
230 volt, single phase-50 Hz 230 volt, single phase-50 Hz
Electrical input power
W
150
150
Electrical protection
IP 44
IP 44
Maximum flow rate for combustion products
10.9
13.5
Fume temperature (60-80)
°C
79
74
Fume temperature (30-50)
°C
60
59
CO
2
G20
%
9.5
9.2
CO
2
G31
%
10
10
Flue duct type
C13 / C33 / C43 / C53
Maximum flue length (Horizontal and Vertical - Ø60/100)
m
5
Maximum flue length (Horizontal and Vertical - Ø80/125)
m
10
SEDBUK
Band (%)
A (90.1)
A (90.3)
Dimensions
HxWxD
mm
720 x 390 x 396
720 x 390 x 360
Weight
kg
31.4
34
Содержание COMBI A 24 MFFI
Страница 19: ...19 1 2 A A Fig 14 Fig 16 Fig 13 11 Installing the Boiler continued Fig 15 P P ...
Страница 22: ...22 Fig 21 Fig 22 Fig 23 ...
Страница 31: ...31 WIRING DIAGRAM FOR CONNECTION TO AN OPEN VENTED CYLINDER DIAGRAM B ...
Страница 32: ...32 WIRING DIAGRAM FOR CONNECTION TO AN MTS UNVENTED CYLINDER DIAGRAM A ...
Страница 61: ...61 24 Benchmark Commissioning Checklist ...
Страница 62: ...62 25 Service Interval Record ...
Страница 63: ...63 ...