45
CH anti cycling delay setting :
If you would like to change the setting of CH anti cycling delay to 3 mins, please proceed as follows:
(
NOTE
: the factory setting is 2 min 30 seconds and the following explanation refers to Menu 4 Section 8)
Display
17. Adjustments and Setting
(continued)
1
5 ”
2
x 3
1
2
or
3
3
4
4
Switch to installer mode, press the
and
keys for 5 seconds, the
display shows :
10
=
0
if there is no
default in the default register.
Press the menu key
three times
to gain access to menu
4,
the display
shows :
40
=
0
or
40
=
1
Change to section 8 (CH anti-cycling
delay), press the
key eight times,
the display shows :
48
=
2.5
(factory
setting 2 min 30 secs)
4
= menu 4
8
= section 8
2.5
= 2.5 min (2 min 30 seconds)
Press the setting key
once, the
3rd and 4th digits flash together.
Then press the
key to change
the CH anti-cycling delay, the display
shows:
48
=
3.0
press the setting key
to
confirm the value. The display stops
flashing.
To exit from setting mode, leave the
boiler for approx. 1 minute the boiler
will automatically switch back to the
user mode.
After programming please close the
door
P
(Fig. 46)
x 8
Содержание COMBI A 24 MFFI
Страница 19: ...19 1 2 A A Fig 14 Fig 16 Fig 13 11 Installing the Boiler continued Fig 15 P P ...
Страница 22: ...22 Fig 21 Fig 22 Fig 23 ...
Страница 31: ...31 WIRING DIAGRAM FOR CONNECTION TO AN OPEN VENTED CYLINDER DIAGRAM B ...
Страница 32: ...32 WIRING DIAGRAM FOR CONNECTION TO AN MTS UNVENTED CYLINDER DIAGRAM A ...
Страница 61: ...61 24 Benchmark Commissioning Checklist ...
Страница 62: ...62 25 Service Interval Record ...
Страница 63: ...63 ...