4
installation
Room thermostat connection
-
Introduce the thermostat wire
- Loosen the cable clamp using a screwdriver and insert the
wires leading from the room thermostat one at a time.
- Connect the wires to the terminals as indicated in the figure
below, removing the link
- Make sure that they are well connected and that they are
not subject to stress when the control panel lid is opened or
closed
- Close the flap again, then replace the control panel cover and
the front casing.
Outdoor sensor connection
-
Introduce the outdoor sensor wires
- Loosen the cable clamp using a screwdriver and insert the
wires leading from the outdoor sensor one at a time.
- Connect the wires to the terminals as indicated in the figure
below;
- Make sure that they are well connected and that they are
not subject to stress when the control panel lid is opened or
closed;
- Close the flap again, then replace the control panel cover and
the front casing.
- Refer to page 39 for setting the parameters when using the
outdoor sensor.
N
ote
:
w
heN
coNNectiNg
the
boiler
to
exterNal
coNtrols
,
do
Not
ruN
240V
cables
aNd
cables
for
switchiNg
circuits
(
which
are
low
Voltage
)
together
,
use
seperate
cables
to
preVeNt
iNduced
Voltage
oN
the
low
Voltage
circuits
.
Connector TA on PCB
(low voltage switching)
CARTE CHAUDIERE
AMPC-GAL1
Transmetteur BU
S
(Optionnel)
Emplacemen
t
ca
rt
e optionnelle
SE
TA1
Connector SE on PCB
Outdoor Sensor
The boiler can be connected to a central heating system that
uses two zone valves to allow connection to an indirect storage
cylinder.
There are two wiring diagrams shown, one for the connection to
an Unvented Cylinder and one for connection to an open vented
cylinder.
In both cases the boiler connection is shown as TA1.
When connecting the boiler to an external cylinder do not run
40V cables and the cables for the room terminal together, use
separate cables to prevent induced voltage on the low voltage
switching circuit.
N
ote
:
t
he
use
of
a
‘y’ p
laN
system
is
Not
possible
with
the
clas
he system
boiler
due
to
the
low
Voltage
switchiNg
of
the
appliaNce
uNless
suitable
relay
coNtrols
are
used
.
Important!!
Ensure that a balancing valve is fitted on the
cylinder return and balanced correctly at
commissioning stage.