settings - adjustment - problem identification menus
Accessing the settings - adjustment - pro-
blem identification menus
The boiler can be used to manage the heating
system in its entirety.
Navigation within the menus enables the
boiler system + connected peripheral units
to be customised, optimising operation for
maximum comfort and maximum saving. It
also provides important information relating
to the efficient operation of the boiler.
The following menus are available:
The parameters relating to each individual menu
are listed in the following pages.
The various parameters can be accessed
and modified using the m
eNu
/o
k
button and
programming buttons
and
.
(see fig.
below).
To access the Menus, open the cover and proceed
as follows:
1. Press the m
eNu
/o
k
button; the first figure
0
00
will flash on the display.
. Press the buttons
or
to select a menu,
for example: “
2
00
3. Press the m
eNu
/o
k
button; the second figures on
the display will flash, e.g. “
2
1
0
.
Caution!
The menus reserved for qualified
technicians may only be accessed after setting
the access code.
4. Press the m
eNu
/o
k
button;
222
will appear on
the display unit.
5. Press the buttons
or
to select code
234
6. Press the m
eNu
/o
k
button to select the sub menu;
the second figures will flash, e.g. “
2
2
0
”.
7. Press the buttons
or
to select a sub
menu; for example: “
2
3
0
8. Press the m
eNu
/o
k
button to access the sub
menu parameters; the three figures will flash, for
example: “
23
0
”.
9. Press the buttons
or
to select a
parameter; for example: “
23
1
10. Press the m
eNu
/o
k
button to access the
parameter; the display will indicate the value, e.g
“
70
”.
Note:
The parameter value will be displayed for
0 seconds, then will begin to flash in alternation
with the parameter, e.g. “
70
>
231
.
11. Press the buttons
or
to select the new
value, e.g. “
75
”.
1. Press m
eNu
/o
k
to save the change or press e
sc
to
exit without saving.
To exit, press the e
sc
button until the normal display
screen is restored.
For menus which do not require the access code, it
is possible to pass directly from the menu to the sub
menu.
2 Boiler Parameter
1 Service code (34)
General setting
3 C.H. Parameters - Part 1
4 C.H. Parameters - Part 1
5 Do not use
9 Menu Reset to factory setting
3 Solar & Storage
3 0 General setting
3 1 Service code (34)
3 Special setting
4 Zone 1 Parameters
4 0 Set-point Zone1
4 1 Service code (34)
4 Zone 1 Setting
4 3 Diagnostics
4 4 Zone device mangement
5
Zone 2 Parameters
5 0 Set-point Zone
5 1 Service code (34)
5 Zone Setting
5 3 Diagnostics
5 4 Zone device mangement
5 5 Multizone
7 Test & Utilities
8 Service Parameter
8 1 Service code (34)
8 Boiler
8 3 Boiler Temperature
8 4 Don’t use
8 5 Service
8 6 Statistics
8 7 E@sy - NOT ACTIVE
8 8 Error History
p
rogrammiNg
buttons
Menu/Ok button
Содержание CLAS HE R 12
Страница 32: ...32 installation S Plan system utilizing integral 2 channel programmer and Ariston unvented hot water cylinder ...
Страница 33: ...33 installation Y Plan system utilizing external 2 channel programmer ...
Страница 34: ...34 installation Y Plan system utilizing integral 2 channel programmer ...