manuale d’uso

Initial operating procedures

If  the  boiler  is  installed  inside  the  apartment,  make  sure  that 

all  provisions  relating  to  the  air  inlet  and  room  ventilation  (in 

compliance with current legislation) are respected.

Check the water pressure on the display regularly and make sure 

that the figure is between 0.6 and1.5 bar when the system is cold. 

If the pressure is just under the minimum   restablish the correct 

pressure by open the valve under the boiler.

If the pressure drops very frequently, there may be a water leak at 

some point in the system. If this is the case a plumber should be 

contacted.

Ignition procedure

Press  the  ON/OFF  button  on  the  control  panel  to  switch  on  the 

boiler. The display shows:

The first figure indicates the operating mode:

0 XX    - Stand -by, 

C XX - Central heating request

c  XX - Heating post-circulation

d  XX - Domestic hot water request

b XX -   Storage

H XX  - Hot water post-circulation

F XX  - Circulation pump anti-freeze protection enabled

    

  - burner anti-freeze protection enabled

The second and third figures indicate:

-   the  flow  temperature  when  no  heating  requests  have  been 

made 

-   the flow temperature in central heating mode 

-   the temperature of the hot water in domestic hot water mode

-  

the flow temperature in anti-freeze mode. ta. 

Winter and Summer Operating Modes

In the “winter” operating mode, the  boiler will produce both Central 

Heating and Domestic Hot Water. In the “summer” operating mode, 

the boiler will produce only Domestic Hot Water.

Using the knob on the control panel, the user can select “winter” or 

“summer” operating mode. Keeping the knob “5” at the “ ” position 

selects  the “summer”  operating  mode. “Winter”  operating  mode 

may be selected by positioning the knob “5” between the min. and 

max. settings.

Adjusting the heating

It is possible to set the temperature of the Central Heating system 

by adjusting the knob “5”. By positioning the indicator somewhere 

between  1  and  6,  a  temperature  may  be  obtained  which  varies 

from approximately 38˚C to about 82˚C.

The  water  temperature  in  the  primary  circuit  is  shown  on  the 

display.

Setting the hot water for domestic use
Both  in  the  winter  and  summer  mode,  the  temperature  of  the 
Domestic  Hot Water  may  be  adjusted  by  using  knob “10”.    A 
delivery temperature for the water may be chosen in a range from 

36˚C to about 56˚C, depending on the flow rate of the water and 
the position of the knob between the min. and max. settings. 
To increase water temperature, turn knob “10” to max. and reduce 
the water flow rate at the tap.
The domestic hot water temperature  is shown on the  display.

To exclude the storage, press the button 17, the Yellow LED 4 lights. 

The boiler will still provide only heating.

Содержание CLAS B 25 CF

Страница 1: ...CLAS B CLAS B Premium GAS BOILER WITH STORAGE CONDENSING BOILER WITH STORAGE CLAS B 25 CF CLAS B 25 FF CLAS B 30 FF CLAS B Premium 25 CLAS B Premium 35 User s Manual ...

Страница 2: ...ppliance Do not allow children or inexperienced persons to use the appliance without supervision CE labelling The CE mark guarantees that the appliance conforms to the follow ing directives 90 396 CEE relating to gas appliances 2004 108 CEE relating to electromagnetic compatibility 92 42 CEE relating to energy efficiency 2006 95 CEE relating to electrical safety Safety regulations Key to symbols F...

Страница 3: ... 9 Esc button 10 Programming key 11 Domestic Hot Water adjustment knob 12 Time clock optional 13 ON OFF Switch 14 Green led auto function activate 15 Auto button to active Thermoregulation 16 Heating only button Control Panel WARNING Installation firstignitionandmaintenanceworkmustbeperformed by qualified personnel only in accordance with the instructions provided Incorrect installation may harm i...

Страница 4: ... temperature in anti freeze mode ta Winter and Summer Operating Modes In the winter operatingmode the boilerwill produce both Central Heating and Domestic Hot Water In the summer operating mode the boiler will produce only Domestic Hot Water Using the knob on the control panel the user can select winter or summer operating mode Keeping the knob 5 at the position selects the summer operating mode W...

Страница 5: ... knob 6 to The boiler will still provide domestic hot water Switching off the boiler To switch off the boiler press the ON OFF button the display will switch off Switch off the boiler completely by switching the external electri cal switch to the OFF position Shut off the gas valve ...

Страница 6: ...mpts to reset the appliance contact a qualified technician IMPORTANT IF THIS SHUTDOWN OCCURS FREQUENTLY CONTACT AN AUTHORISED SERVICE CENTRE FOR ASSISTANCE FOR SAFETY REASONS THE BOILER WILL ALLOW A MAXIMUM OF 5 RESET OPERATIONS TO TAKE PLACE IN 15 MINUTES INDIVIDUAL PRESSES OF THE BUTTON IF THE SHUTDOWN IS OCCASIONAL OR AN ISOLATED EVENT THIS IS NOT A PROBLEM Operation shutdown error table Tempor...

Страница 7: ... on less cold days of which there are many more typical of the autumn and winter seasons This habit leads to excessive room heating after the thermostat has been switched off resulting in energy waste and uncomfortable conditions inside the room The new AUTO function takes control of the boiler and selects the best operating regime based on environmental conditions external devices connected to th...

Страница 8: ...Ariston Thermo SpA Viale A Merloni 45 60044 Fabriano AN www aristonthermo it info it aristonthermo com ...

Отзывы: