39
GB
0
OFF
1
ON
Turn the knob and set value 1 to activate
the anti-Legionnaire's disease function.
Press the OK button.
The display will visualise the selected set-
ting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
-
3 2 1 Hydraulic scheme
Turn the knob to check or set the reference
hydraulic circuit diagram according to the
installation performed:
0
Not
defi ned
1
Basic
single-coil
2
Basic
double-coil
3
Solar-electric
4
Heating
integration
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 2 Electric resistance setting
Press the OK button.
Turn the knob and set value 1 if the user
desires that the heating integration - via
the heating element - occurs according to
a time schedule.
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 3 Collector DeltaT pump ON
Press the OK button.
Turn the knob and set the temperature dif-
ference between the collector and storage
tank that determines the pump's activa-
tion.
NOTE: INCREASE THE VALUE IF THE
PUMP TURNS ON/OFF FREQUENTLY.
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 4 Collector DeltaT pump OFF
Press the OK button.
Turn the knob and set the temperature dif-
ference between the collector and storage
tank that determines the pump's stoppage.
NOTE: DECREASE THE VALUE IF THE
PUMP TURNS ON/OFF FREQUENTLY.
Press the OK button.
The display will visualise the selected set-
ting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 7 Recooling Function
Press the OK button.
Turn the knob and set value 1 to activate
the Recooling function.
NOTE: this function delays overheating of
the collector by cooling the indirect cylin-
der during the night.
Press the OK button.
The display will visualise the selected setting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
- 3 2 9 Collector Frost Protection T
Press the OK button.
Turn the knob and set value 0 for enhancing
the anti-freeze protection for the collector.
Set -20 if high percentages of glycol are
used.
Press the OK button.
The display will visualise the selected set-
ting.
Press OK button to return to the previous
visualisation.
Turn the knob and select:
-
3 6 0 Flow rate solar circuit
The display will visualise the value of the
fl ow rate in the solar circuit.
(IMPORTANT: ADJUST THE FLOW RATE
ACCORDING TO THE NUMBER OF COL-
start-up
Содержание Chaffoteaux 3318905
Страница 4: ...4 IT descrizione prodotto 275 62 480 125 125 200 DIMENSIONI STAFFA DI SUPPORTO 40 Ø 9 Ø 9 9 ...
Страница 26: ...26 GB product description 275 62 480 125 125 200 DIMENSIONS MOUNTING BRACKET 40 Ø 9 Ø 9 9 ...
Страница 48: ...48 FR description du produit 275 62 480 125 125 200 DIMENSIONS PLAQUE DE SUPPORT 40 Ø 9 Ø 9 9 ...
Страница 70: ...70 ES descripción del producto 275 62 480 125 125 200 DIMENSIONES ESTRIBO DE SOPORTE 40 Ø 9 Ø 9 9 ...
Страница 92: ...92 PT descrição do produto 275 62 480 125 125 200 DIMENSÕES SUPORTE 40 Ø 9 Ø 9 9 ...
Страница 112: ...112 B A Schema impianto Installation scheme schéma d installation Instalación de sistema esquema de instalação ...
Страница 113: ...113 IT B A C Schema impianto Installation scheme schéma d installation Instalación de sistema esquema de instalação ...
Страница 114: ...114 ...
Страница 115: ...115 ...