![Ariston AG LNX 500 Скачать руководство пользователя страница 60](http://html.mh-extra.com/html/ariston/ag-lnx-500/ag-lnx-500_installation-and-maintenance-instructions-manual_2971876060.webp)
60
GB
TECHNICAL DATA
Supplier’s model identi
fi
er
SGA X 500
AG LNX 500
TES X 500
Model
500
Certi
fi
cate CE
051CT4892
Nominal capacity
I
500
Real capacity
I
447
Nominal pressure
bar
7
Nominal heat rating
kW
22,5
Useful rating
kW
19,4
Heating time for DHW t 45°C
min.
72
Hot water
fl
ow rate
supply at 30K
I/h
556
Erp DHW
Declared Load pro
fi
le
XXL
Water heating e
ffi
ciency
η
wh
%
65
Water Heating e
ffi
ciency class
B
Daily electricity consumption Q
elec
kWh
--
Daily fuel consumption Q
fuel
kWh
37,940
Sound power level LWA L
WA
dB
59
Emissions of nitrogen oxides
[mg/kWh]
33
Annual electricity consumption AEC
kWh/annum
--
Annual fuel consumption AFC
GJ/annum
28,1
Mixed water at 40°C V40
l
690
Set-point temperature “out of the box”
°C
50
Thermostat temperature settings
4
Gas supply pressure
G20 Methane
mbar
20
G30 Butane LPG
mbar
28 ÷ 30
G31 Propane LPG
mbar
37
gas consumption
G20 Methane
m
3
/h 2,38
G30 Butane LPG
m
3
/h
1,77
G31 Propane LPG
Kg/h 1,75
Combustion gas values
Draught
mbar
0,015
Flue gas
fl
ow rate
g/sec
88
Flue gas temperature
°C
129
For the list of equivalent models refer to Annex A, an integral part of this booklet.
The products without the label and its board for sets of heaters and solar devices, provided for in Regulation 812/2013,
are not intended for use in such sets.
Содержание AG LNX 500
Страница 16: ...16 IT A E C D B F F3 F4 F1 F2 ...
Страница 36: ...36 FR A E C D B F F3 F4 F1 F2 ...
Страница 56: ...56 GB A E C D B F F3 F4 F1 F2 ...
Страница 61: ...61 ...
Страница 62: ...62 ...
Страница 63: ...63 ...