91 / GB
MENU
SUB-MENU
PARAMETER DESCRIPTION
RANGE
DEFAULT
5
5
2
Thermoregulation type
ON/OFF
Fix Flow T
Outdoor T Only
ON/OFF
5
5
3
Slope
[18;33] FC; [0-30] UFH
25 FC; 10 UFH
5
5
4
Offset
[-2,5°C; +2,5°C]
0°C
5
5
6
Max T
MinT -12°C [FC];
MinT - 23°C [UFH]
12°C [FC];
23°C [UFH]
5
5
7
Min T
7°C-MaxT [FC]; 18-MaxT [UFH]
7°C [FC];
18°C [UFH]
5
5
8
Target deltaT for pump modulation cooling
[-5; -20°C]
-5°C
7
ZONE MODULE (if present)
7
1
Manual Mode
7
1
0
ZM Manual mode activation
OFF - ON
OFF
7
1
1
Z1 Pump control
OFF - ON
OFF
7
1
2
Z2 Pump control
OFF - ON
OFF
7
1
4
Z2 Mix Valve Control
OFF
Open
Close
OFF
7
2
General Zone Module
7
2
0
Hydraulic scheme definition
Not defined
MCD
MGM II
MGM III
MGZ I
MGZ II
MGZ III
MGM II
7
2
1
FlowT Offset
0
7
2
2
Auxiliary output setting
Heat request
External pump
Alarm
Heat request
7
2
3
External temperature correction
- 3 ÷ +3°C
0°C
7
3
Cooling
7
3
0
Flow_T_offset_Cool
[ 0÷ 6°C]
0°C
7
8
Error History
7
8
0
Last 10 Errors
7
8
1
Reset Error List
Reset? OK=Yes,esc=No
7
8
2
Last 10 Errors 2
7
8
3
Reset Error List 2
Reset? OK=Yes,esc=No
7
9
Reset Menu
7
9
0
Reset Factory Settings
Reset? OK=Yes,esc=No
17
HP SYSTEM PARAMETERS
17
0
User Parameters
17
0
0
CH mode
Mode Green
Mode Standard
Mode Green
17
0
1
Quiet Mode Activation
OFF - ON
OFF
17
0
2
Quiet Mode start time [hh:mm]
[00:00-24:00]
22:00
17
0
3
Quiet Mode end time [hh:mm]
[00:00-24:00]
06:00
17
0
4
Domestic Hot Water BOOST
OFF - ON
OFF
17
0
5
PV Delta T DHW setpoint temp.
0 ÷ 20°C
0°C
17
1
EM Input Output Configuration
17
1
0
HV Input 1
Not Defined
Absent
EDF
SG1
External switch off signal
Absent