Страница 1: ...Quick Start Guide Awake Security Appliance DCA NDR S1 DCA NDR S5 DCA NDR NB10 DCA NDR A5 Arista Networks www arista com DOC 05228 01 ...

Страница 2: ...demarks of Arista Networks Inc in the United States and other countries Other product or service names may be trademarks or service marks of others Headquarters 5453 Great America Parkway Santa Clara CA 95054 USA 1 408 547 5500 www arista com Support 1 408 547 5502 1 866 476 0000 support arista com Sales 1 408 547 5501 1 866 497 0000 sales arista com ...

Страница 3: ...ances 7 3 2 Installing 2RU Awake Security appliances 9 Chapter 4 Cabling the Appliance 13 Chapter 5 Configuring the Awake Security Platform 15 5 1 Connecting to the Admin CLI 15 5 2 Configuring the Appliance 15 5 2 1 Configuring the Management Interface 15 5 2 2 Configuring DNS 16 5 2 3 Configuring NTP 16 5 2 4 Configuring Proxy 16 5 2 5 Configuring IPMI DRAC Interface 16 5 3 Verifying the Configu...

Страница 4: ...Appendix E Regulatory Model Numbers 29 iv ...

Страница 5: ...Nucleus Appliance DCA NDR A5 2RU All in One Appliance Note Only qualified personnel should install service or replace this equipment Seul le personnel qualifié doit installer service ou remplacer cet équipement 1 2 Receiving and Inspecting the Equipment Upon receiving the Awake Security appliance s inspect the shipping boxes and record any external damage Retain packing materials if you suspect th...

Страница 6: ...ements fédéraux 21 CFR 1040 ne soit pas dépassée après avoir installé l émetteur récepteur de laser Ne pas installer des appareils à laser dont la cote de classe est supérieure à 1 Voir toutes les consignes de sécurité qui ont accompagné l émetteur récepteur avant l installation Seuls appareils laser de classe 1 certifiés pour une utilisation dans le pays d installation par l organisme compétent d...

Страница 7: ...Awake Security appliance Specifications RUs Dimensions and Weight Awake Security appliance SKU Rack Units RUs Dimensions W x H x D Weight DCA NDR S1 1 43 7 x 4 3 x 65 0 cm 17 2 x 1 7 x 25 6 in 20 87 kg 46 lbs DCA NDR S5 2 43 7 x 89 0 x 72 3 cm 17 2 x 3 5 x 28 5 in 32 7 kg 72 0 lbs DCA NDR NB10 2 43 7 x 89 0 x 72 3 cm 17 2 x 3 5 x 28 5 in 32 7 kg 72 0 lbs DCA NDR A5 2 43 7 x 89 0 x 72 3 cm 17 2 x 3...

Страница 8: ...4 ...

Страница 9: ...it is the only item in the rack Other Requirements Select a site where liquids or objects cannot fall onto the equipment and foreign objects are not drawn into the ventilation holes Verify these guidelines are met Clearance areas should be maintained in the front and rear panels allow for unrestricted cabling and access to the switches and controls All front and rear panel indicators can be easily...

Страница 10: ...avoid ESD damage when installing or servicing Awake Security appliances Assemble or disassemble equipment only in a static free work area Use a conductive work surface such as an anti static mat to dissipate any static charge accumulation Wear a conductive wrist strap to dissipate any static charge accumulation Minimize handling of assemblies and components Keep replacement parts in their original...

Страница 11: ...Security appliance 1 Identify the left and right outer rails by examining the ends which bend outward Slide the matching inner rails into the corresponding outer rails to be sure they are ready for installation Note The rail set fits a rack between 25 6 and 33 deep 2 Position the alignment pins in the rear rail 2 with the hole at the end of the slot in the front rail 1 and slide the front section ...

Страница 12: ...e rack 6 Repeat the procedure for the other outer rail assembly Figure 2 Rack Rails Installed Note Ensure that the appliance includes the inner rails and inner rail extensions and the outer rails are installed on the rack 7 Align the appliance inner rails with the front of the outer rails on the rack 8 Slide the appliance rails into the rack rails keeping the pressure even on both sides 8 ...

Страница 13: ...tely into the rack you should hear the bracket clip locks with an audible click 9 Insert and tighten the thumbscrews that hold the front of the server to the rack 3 2 Installing 2RU Awake Security appliances Perform the following steps to install a 2RU Awake Security appliance 1 Detach the inner rails from the outer rails Figure 4 Detaching Rails 2 Install the inner rails to the side of the applia...

Страница 14: ... Install inner rails 3 Press the button to slide the rail in Figure 6 Slide the Rail in 4 Secure the rack to the rail with screws Figure 7 Screw in the rails 5 Repeat the previous step to mount four corners 10 ...

Страница 15: ...gure 8 Mount all four corners 6 Insert the appliance rails into the rack rails and slide the appliance all the way in Figure 9 Positioning the appliance 7 Install screws into the handles to secure the appliance Figure 10 Securing the Appliance 11 ...

Страница 16: ...12 ...

Страница 17: ... for your installation For a single nucleus installation interconnect ports are unused and should not be connected For a dual nucleus installation connect a network cable from the first nucleus interconnect port to the second nucleus interconnect port For a nucleus cluster with more than two nucleus appliances attach a network cable from one of the interconnect ports from each nucleus and connect ...

Страница 18: ...14 ...

Страница 19: ...ommand Prompt Window Note Enter the username as admin and the password provided by the Awake support 5 2 Configuring the Appliance Configure the following networking parameters in Awake Security appliances Configuring the Management Interface Configuring DNS Configuring NTP Configuring Proxy Configuring IPMI DRAC Interface Note If you are configuring all networking parameters simultaneously you ca...

Страница 20: ...must configure the Network Time Protocol NTP in all of your Awake appliances to ensure the accuracy of the appliance clock Perform the following steps to configure NTP 1 Enter the set ntp servers command An interactive prompt will ask for primary and secondary servers 2 Enter the primary and secondary servers 3 Enter the apply command to apply the changes 4 If no further configuration changes are ...

Страница 21: ...ateway The default gateway of the network Would you like to change the ipmi admin password Enter y to configure the IPMI password else enter n Note The default password is printed on a label on the appliance The password can be shared if it is configured by the Awake team The password should not exceed 20 characters and must contain numbers uppercase letters and symbols 3 Enter the apply command t...

Страница 22: ...18 ...

Страница 23: ...ors Front panel LEDs are located on the upper right corner of the device for 1RU Awake appliances 1 UID LED 5 HDD LED 2 Information LED 6 Power LED 3 NIC2 LED 7 Reset button 4 NIC1 LED 8 Power button Figure 12 DCA NDR S1 Front panel LEDs are located on the lower left corner of the device for 2RU Awake appliance Figure 13 DCA NDR A5 DCA NDR NB10 DCA NDR S5 1 Power button 5 Information LED 2 Reset b...

Страница 24: ...rs DCA NDR A5 DCA NDR S5 Packet Capture Port LEDs 1 Link LEDs 2 Activity LEDs Label Indication Meaning Green Linked at 10 Gb Link Yellow Linked at 1 Gb Blinking Actively transmitting or receiving data Activity Off No link DCA NDR NB10 Interconnect Port LEDs 1 Link LED 3 Link LED 2 Activity LED 4 Activity LED Label Indication Meaning Off Not linked to the LAN Green Linked at 10 Gb Link Yellow Linke...

Страница 25: ...ta activity Activity Link Off No link Off 10 Mbps Green 100 Mbps 10 Off 100 Green 1000 Yellow Yellow 1000 Mbps IPMI LAN Port LEDs 1 Link LED The green amber or off indicates the speed of the connection 2 Activity LED The yellow LED indicates activity Table 2 IPMI Link LEDs LED Color Definition Amber Solid 1 Gb s Green Solid 100 Mb s Off No connection or 10 Mbps 21 ...

Страница 26: ...22 ...

Страница 27: ...his appendix lists the installation parts contained in the accessory kit Figure 14 Awake Accessory Kit 1 Inner rails 4 Screws 2 Rear rails 5 AC Power cables 3 Front rails B 1 Cables A pair of AC power cables part number NEMA 5 15p is included in the accessory kit Note All provided power cables are for use with Arista products only 23 ...

Страница 28: ...24 ...

Страница 29: ... 19 rack The appearance may be different than those shown based on PSU and fan modules used Figure 15 DCA NDR S1 1 Unused port 4 Right rack ear brackets 2 Unused port 5 Hard drive carrier 3 Control panel 6 Left rack ear brackets Figure 16 DCA NDR A5 DCA NDR NB10 DCA NDR S5 Table 3 1 NVMe A5 and NB10 only 3 Service Asset tag 2 Storage drives 4 Control panel 25 ...

Страница 30: ...26 ...

Страница 31: ...than those shown based on the PSU types and the modules used DCA NDR S1 1 IPMI LAN port 7 Unused port 2 Unused slot 8 Management port 3 Packet capture ports 9 USB ports 4 Unused slot 10 COM port 5 UID LED 11 Power supplies 6 VGA DCA NDR A5 DCA NDR S5 1 Unused slot 7 COM port 2 Packet capture ports 8 IPMI LAN ports 3 SSD drives 9 USB ports 4 Unused slots 10 Management port 5 VGA 11 Power supplies 2...

Страница 32: ...6 UID LED DCA NDR NB10 1 Unused slot 7 COM port 2 Interconnect ports 8 IPMI LAN ports 3 SSD drives 9 USB ports 4 Unused slots 10 Management port 5 VGA 11 Power supplies 6 UID LED 28 ...

Страница 33: ...mbers RMNs for the product models of the Awake Security appliances described in this document Table 4 Regulatory Model Numbers and Product Numbers Regulatory Model Numbers RMNs Product Numbers 815 R5H12 DCA NDR S1 829UAS 16 DCA NDR A5 829UAS 16 DCA NDR NB10 829UAS 16 DCA NDR S5 29 ...

Страница 34: ...30 ...