background image

 

12. Please keep the product from the wall or other 

barriers in a minimum distance of 50 cm. 

13. Please install the appliance following the country 

wiring laws. 

 
OPERATING INSTRUCTION 
 

1.  Control panel

 

2.  Air outlet 

3.  Handel 

4.  Front housing 

 

 

 

 

 

 

 

 

 

5.    Air Inlet / Back housing 

6.  Drain hole 

7.  Water tank 

 

 

 

 

3

CONTROL PANEL DESCRIPTION

 

 

OPERATING INSTRUCTION 

 

STARTING THE UNIT

   

1.  Firstly, turn the humidity control switch to the “OFF” position. 

2.  Plug in the dehumidifier. 

3.  Turn on the humidity control switch(to right side) and turn the same 

switch to the reading of the desired humidity(60% in general as shown 

on position”4”). 

 

TURNING OFF THE UNIT

 

 

1.  Turn the humidity control switch to the left side to the “OFF” position to 

cut off the power supply, then the unit stops operating. 

2.  If the dehumidifier is not in use for a long time, please disconnect the 

power cord plug from the outlet. 

 
WARNING 

1.  When operating the dehumidifier, please do not set the humidity higher 

than ambient humidity. 

2.  When indicating light illuminates, please pour the water out of the tank 

and put it back. Then the product will resume working. 

3.  When the product shut down, please wait at least 3 minutes before 

restarting the unit to prevent damaging the compressor. 

Содержание PD40-LAR

Страница 1: ...ving or cleaning the product and also when the product is not in used 6 Please operate the product with specified electricity voltage 7 Please use this product only for household appliance and follow the designed purpose 8 Do not put any stuff on the product 9 In order to avoid water leakage please clean the water tank before moving the product 10 Do not incline the product or leaking water may da...

Страница 2: ...rn the same switch to the reading of the desired humidity 60 in general as shown on position 4 TURNING OFF THE UNIT 1 Turn the humidity control switch to the left side to the OFF position to cut off the power supply then the unit stops operating 2 If the dehumidifier is not in use for a long time please disconnect the power cord plug from the outlet WARNING 1 When operating the dehumidifier please...

Страница 3: ...ated indicating light will illuminate DRAINING INSTRUCTION Draining water can storage in the water tank or be continuous drained by PVC tube The PVC tube is not included in the product 5 USAGE OF WATER TANK When dehumidifying the condensing water may be drained to water tank And the unit will stop working with indicating light illuminates when the water tank is full of water please pour out the wa...

Страница 4: ...r dried naturally 7 SPECIFICATIONS Model Specification PD40 LAR Power Supply 220 240V 50Hz Power Input 700W Rated Current 3 2A Net Weight 19 5Kg Moisture Removal 30 RH80 40 liters day Dimension W x D x H mm 481W x 286D x 628H Applicable temperature 5 32 Water Tank Capacity 7 2L CE N 842 2006 R410A is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol Its total global warming pote...