background image

 

4.  The humidity and its related position number on the humidity control 

switch: 

 

CONTROL SWITCH 

POSITION NO. 

APPROXIMATE 

HUMIDITY SETTING

20

 

30

 

40

 

 60

 

 80

 

 

5.  The applicable operating temperature range for this unit is 5-32

.

 

6.  If the dehumidifier can’t start (the indicating light does not illuminate) or 

the dehumidifier shut down unreasonably, please make sure whether 

the plug is connected firmly to power supply. If the plug and power 

supply are in normal condition, please wait for 10 minutes before restart 

the unit (because it takes 10 minutes to reposition). If the unit still does 

not start in 10 minutes, please ask your local distributor service station 

to repair. 

7.  When the dehumidifier is operating, it’s a normal situation that the 

working compressor may cause some heat and bring the ambient 

temperature up. 

8.  When the product is defrosting, related indicating light will illuminate. 

 

DRAINING INSTRUCTION 

Draining water can storage in the water tank, or be continuous drained 

by PVC tube. (The PVC tube is not included in the product.) 

 

 

5

USAGE OF WATER TANK 

When dehumidifying, the condensing water may be drained to water 

tank. And the unit will stop working with 

indicating light illuminates when the water tank is 

full of water, please pour out the water that time. 

1.  Take out the water tank as Fig 01, and pour 

out the water. 

2.  Put the water tank back. 

3.  The unit follows the setting humidity to 

operate automatically. 

 

CONTINUOUS DRAINAGE   

1.  Before continuous draining water, please 

take out the water tank and plug a draining 

tube to draining hole (See Fig 02.) Then put 

the water tank back.

 

2.  Draining tube should place lower than the 

draining hole to let water flow out. 

 

FILTER REMOVAL 

1. To remove the filter please press the 

filter's buckles down, and then remove 

the filter directly. 

2.    Wash the filter with cool water (cooler 

than 40

) every two weeks, and put 

filter back after it air-dried naturally. 

 

 

Fig 01

 

Fig 02

 

Содержание PD40-LAR

Страница 1: ...ving or cleaning the product and also when the product is not in used 6 Please operate the product with specified electricity voltage 7 Please use this product only for household appliance and follow the designed purpose 8 Do not put any stuff on the product 9 In order to avoid water leakage please clean the water tank before moving the product 10 Do not incline the product or leaking water may da...

Страница 2: ...rn the same switch to the reading of the desired humidity 60 in general as shown on position 4 TURNING OFF THE UNIT 1 Turn the humidity control switch to the left side to the OFF position to cut off the power supply then the unit stops operating 2 If the dehumidifier is not in use for a long time please disconnect the power cord plug from the outlet WARNING 1 When operating the dehumidifier please...

Страница 3: ...ated indicating light will illuminate DRAINING INSTRUCTION Draining water can storage in the water tank or be continuous drained by PVC tube The PVC tube is not included in the product 5 USAGE OF WATER TANK When dehumidifying the condensing water may be drained to water tank And the unit will stop working with indicating light illuminates when the water tank is full of water please pour out the wa...

Страница 4: ...r dried naturally 7 SPECIFICATIONS Model Specification PD40 LAR Power Supply 220 240V 50Hz Power Input 700W Rated Current 3 2A Net Weight 19 5Kg Moisture Removal 30 RH80 40 liters day Dimension W x D x H mm 481W x 286D x 628H Applicable temperature 5 32 Water Tank Capacity 7 2L CE N 842 2006 R410A is a kind of fluorinated greenhouse gases covered by the Kyoto Protocol Its total global warming pote...

Отзывы: