ARIB STD-T91
-24-
Figure A3-1 A measurement schematic diagram used for the measurement example
(2) Equipment for an experiment
A list of equipment used for the measurement experiment is shown in Table A3-2:
Table A3-2 Equipment for experiment
Equipment name
Manufacturer
Model Qtty
Remarks
UWB radio equipment
1
ATT HP
8495B
8494B
1 DC-18
GHz
1 dB, 10 dB step
LPF Mini-Circuits BPF-750
1
750 MHz LPF
AMP R&K
A-528-LN
1
0.01 - 1 GHz, 32 dB
Spectrum analyzer
Anritsu
MS8901A
1
9 kHz - 3 GHz
(3) Characteristics of LPF and AMP
The transmission characteristics when combining LPF and AMP in the measurement
example are shown in Figure A3-2. Frequency characteristics for “LPF input signal” and
“(AMP output signal) – (AMP gain) + (LPF insertion loss)” are shown here. In the
measurement example, attenuation of 50 dB or more was obtained in the frequency band
between1.5 GHz and 10 GHz by combining LPF and AMP.
UWB Radio
Equipment
ATT
AMP
LPF
Spectrum
Analyzer