![Aria Aria-130 Скачать руководство пользователя страница 91](http://html1.mh-extra.com/html/aria/aria-130/aria-130_installation-manual_2969635091.webp)
Aria-130 Digital Key Telephone System
Issue: 1.2
Installation Manual
91
Function of various connectors
Connector
Function
Remark
CN1
Serial interface connector( 4pin) for trace
Note 1
CN2
For the purpose of development
Note 2
CN3, CN6, CN7
Not used
CN4~CN5
VCEU expansion connector
CN8~CN9
FMEU expansion connector
PJ1, PJ2
Not used
Table 3.4.49 Connector on VMIB
•
Note:
1. CN1: Trace for the purpose of development and maintenance.
The external module for RS-232C serial interface should be required for trace using this
connector. See GDK-TRC1 in section 2.4.15.
2. CN2: It is impossible to use them for user access.
These connectors are usually used for the purpose of development and production test.
Function of various switches
Switch
Function
Remark
SW1
SRAM back-up when power interruption or failure
ON
SW2
CPU reset
SW3, SW5
Not used
Not Used
SW4
Service/Normal
Normal
Table 3.4.50 Switch on VMIB
•
Note:
1. SW1: This is for the purpose of SRAM back-up for ACD/UCD announcement.
It should be turned ON during installing the VMIB, to protect announcements in the case of a
power fail.
“ Caution :
Not function properly if battery is incorrectly replaced. Replace only with the same or
equivalent type recommended by the manufacturer. Dispose of used batteries according
to the manufacturers instruction.”
2. SW4 : This is for the purpose of the state of “in service” or “normal operation”.
3. VMIB can be installed in the universal slot No 1 ~ 6 of any KSU.
Add-on boards: FMEU, VCEU
Содержание Aria-130
Страница 4: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 4 Blank sheet...
Страница 9: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 9...
Страница 47: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 47 Figure 3 3 1 KSU Exterior...
Страница 57: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 57 Figure 3 3 10 a Power Supply Unit...