Aria-130 Digital Key Telephone System
Issue: 1.2
Installation Manual
86
•
Note
1. CON1: Trace for the purpose of development and maintenance.
The external module for RS-232C serial interface should be required for trace.
See GDK-TRC1 in section 2.4.15.
2. CON3, CON4: They are used to control the reference clock signal when multi-ISDN boards
are installed. See
[Clock Control Cable Wiring]
on section 3.5.7.5.
The line connector and termination switches
Line No
RJ45 type
Jack
S/T selection
Terminating Resistors
Switch
all to “T “
All to “S”
Switch
all to ON
all to OFF
Line 1
CON8
SW4
T
S
SW9
terminating
open
Line 2
CON7
SW3
T
S
SW8
terminating
open
Line 3
CON6
SW2
T
S
SW7
terminating
open
Line 4
CON5
SW5
T
S
SW6
terminating
open
Table 3.4.44 Line connector on STIB
•
Note:
1. The setting method of S/T selection switches: default -all T position while delivering the
board.
2. Each line interface can be used for T interface or S interface with different operation
interface. If necessary, the S/T selection switches of SW2, SW3, SW4 and/or SW5 can be
respectively set to the T or S position by using shorting traps (short pins) supplied on the
boards.
3. Two poles of SW6, SW7, SW8 and/or SW9 should set to the ON position to terminate two
terminating resistors on a line. (default ON)
4. Terminating resistors and selectable switches are introduced only on PCB issue 2 or
later, but not on PCB issue 1. So if you use STIB issue 1, the external terminating
resistors are required. For the external termination, you can get the terminating unit
locally or use GDK-162/100 TERM, which is the terminating unit with 4 P-to-P
connection provided by LG.
Figure 3.4.18 Configuration of S/T selection connectors
•
Note:
1. Each line can be selected to T or S interface according to the needs.
2. After setting all lines respectively, the slot(s) of STIB must be assigned as CO slot(s) and
STA slot(s) together in Admin field 02 for the proper operation of STIB. See the clause 4.2
and the Programming Manual.
Power does not feeding
Power feeding
POWER
T
S
SW2/SW3/SW4/SW5
Shorting
trap
Содержание Aria-130
Страница 4: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 4 Blank sheet...
Страница 9: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 9...
Страница 47: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 47 Figure 3 3 1 KSU Exterior...
Страница 57: ...Aria 130 Digital Key Telephone System Issue 1 2 Installation Manual 57 Figure 3 3 10 a Power Supply Unit...