![Aria 600 Скачать руководство пользователя страница 157](http://html.mh-extra.com/html/aria/600/600_programming-manual_2969633157.webp)
Aria-24/130c/130/300/600
ipe
Digital Key Telephone System Issue: 1.6
Programming Manual
157
11
LCR
To program LCR, press the
[TRANS/PGM]
button and dial 220 - 223. There are 4 parts in the LCR
table. User can program general database, LCR access mode, day zone and time zone by PGM 220.
PGM 221 is for Leading Digit Table and PGM 222 is for Digit Modification Table. The stored database
for LCR may be initialized by PGM 223.
11.1 LCR ATTRIBUTES (PGM 220)
PROCEDURE
LCR CONTROL ATTRIBUTES
PRESS FLEX_KEY (1-5)
(1)
[TRANS/PGM]
+ 220.
LCR ACCESS MODE (1-6)
(M00) DISABLE LCR
(2) Flex BTN 1: Change LCR access mode
Dialing digit 1-6, the LCD will show the changed value M00,
M01, M02, M11, M12 or M13. See the Table 10.1.1.
LCR ACCESS MODE (1-6)
(M02) INT AND LOOP LCR
For example, dial 3 and press the
[HOLD/SAVE]
button to
save the changed data.
DAY ZN 1:1234567 2: 3:
M1 T2 W3 T4 F5 SA6 SU7
(3) Flex BTN 2: Set the day-of-week zone
To set the day zone, dial the associated zone number
following the Flex. BTN related with weekday. (BTN 1 for MON,
BTN 2 for TUE, BTN 3 for WED, etc.)
For example, if you want to set Saturday as zone 2, then press
BTN 6, dial 2 and press the
[HOLD/SAVE]
button.
DAY ZN 1:123457 2:6 3:
MON : ZONE 3 (1
–3 )
Confirmation tone is heard and the LCD will be changed.
Ex) To set the Monday as zone 3, press BTN 1. LCD shows
current zone of Monday. And dial the desired zone 3. The
changed value will be displayed on the LCD.
DAY ZN 1:23457 2:6 3:1
M1 T2 W3 T4 F5 SA6 SU7
Press the
[HOLD/SAVE]
button. Confirmation tone is heard
and LCD will be changed.
TIME ZONE 1
1:00-24 2: . .-. . 3: . .-. .
(4) Flex BTN 3: Set the time-of-day zone 1
TOD1 (24HOUR FORM)
1:00-24 2:..-.. 3:..-..
To enter value, choose the zone by pressing Flex. BTN and dial
the time range (BTN1 for zone 1, BTN 2 for zone 2, BTN 3 for
zone 3).
For example, if you want to set time zone as Zone 1: 08-18
Zone 2: 18-24 Zone 3: 24-08, then, press BTN 1, dial 0818 and
press the
[HOLD/SAVE]
button, BTN 2, dial 1824 and
[HOLD/SAVE]
button, and press BTN 3, dial 2408, and
[HOLD/SAVE]
button.