![Aria 600 Скачать руководство пользователя страница 110](http://html.mh-extra.com/html/aria/600/600_programming-manual_2969633110.webp)
Aria-24/130c/130/300/600
ipe
Digital Key Telephone System Issue: 1.6
Programming Manual
110
6.2
SYSTEM ATTRIBUTE - II (PGM 161)
PROCEDURE
SYSTEM ATT 2
PRESS FLEX_KEY (1-15)
(1)
[TRANS/PGM]
+ 161.
NETWORK TIME/DATE
(1 : ON/ 0: OFF) : OFF
(2) To program, use the Flex. BTNs as Table 5.2.1. Press one of
the Flex. BTNs 1-
15
. (EX. Flex. BTN 1) Entering a desired
value, the LCD shows the changed value.
NETWORK TIME/DATE
(1 : ON/ 0: OFF) : OFF
(3) Press the
[HOLD/SAVE]
button for updating database
permanently when setting values in each Flex. BTN.
SYSTEM ATT 2
PRESS FLEX_KEY (1-15)
Press the
[CONF]
button instead of the
[HOLD/SAVE]
button,
then system goes to step (1) without updating system memory
BTN
ITEM
RANGE
DEFAULT
REMARK
1
Network Time/Date
Setting
On/Off
OFF
If this field is ON, the system time/date are set by the
network time/date.
2
Off-Hook Ring Type
Mute/
Burst
MUTE
The off-hook ring type in the system can be set to
mute or one burst ring.
3
Override 1st CO Group
On/Off
ON
If there is no available CO line in the 1st CO group,
system can access the next accessible CO group
when this field is ON.
4
Page Warning Tone
On/Off
ON
If desired, page warning tone can be suppressed.
5
Auto Privacy
On/Off
ON
The system can be programmed to override CO line
call to gain access to the conversation. If privacy is
disabled, a station privileged to override in PGM113-
BTN 4 joins an existing call in progress.
6
Privacy Warning Tone
On/Off
ON
If desired, privacy warning tone can be suppressed.
7
Single Ring for CO Call
Yes/No
NO
Changes a cadence of ICM or incoming CO ring. In
case of NO: - ICM: 1sec on/ 4sec off
CO : 0.4s on/ 0.2s off/ 0.4s on/ 4sec off
In case of YES, the cadence is the reverse.
8
WTU Auto Release
On/Off
OFF
Enable or disable auto release of WTU
9
ACD Print Enable
1:10s/
0 :Off
OFF
Enable or disable ACD Print feature
10
ACD Print Timer
001
–255
(3 Digits)
001
Determines the amount of time between repeated
ACD database prints. (10 sec or 1 hour base)
11
Clear ACD Database after
Print
On/Off
OFF
Determines that initialize ACD database after print-
out.
12
VMIB Prompt Gain
00-31
08
To control prompt gain level.
13
VM with CLI Info
On / Off
OFF
When Voice Mail information printed through RS232
port by SMDI, if this is
„ON‟, CLI is added.
14
ACD Print Timer Unit
Hour/
Sec
SEC
Determines the unit of ACD Print timer of Flex Btn 10
(1 hour or 10 seconds).
15
Set VM SMDI Type
Type Ii/
Type I
TYPE I
Set VM SMDI type (Refer RS232 Spec).
16
Incoming Call Toll Check
On / Off
Off
Enable or disable to toll check for incoming call
17
Reserved