1.  SAFETY INSTRUCTIONS 

 

General 

1.

 

A.R.I. products always operate as components in a larger system. It is essential for the system designers, installers, 
operators and maintenance personnel to comply with all the relevant safety standards. 

2.

 

Installation, operation or maintenance of the product should be done only by qualified workers, technicians and/or 
contractors  using  only  good  engineering  practices,  complying  with  and  observing  all  conventional  safety 
instructions  in  order  to  minimize  risk  and/or  danger  and/or  hazard  to  workers,  the  public  or  to  property  in  the 
vicinity in accordance with all relevant local standards. 

3.

 

Extra  safety  considerations  should  be  taken  with  hot  and  hazardous  liquids  or  in  hazardous  environments' 
applications to avoid bodily/physical harm and damage to public or private property. 

4.

 

All individuals installing operating and/or handling the products including all workers should at all times adhere to 
the  occupational  safety  and  health  (OSH)  instructions  and  wear  safety  helmets,  goggles,  gloves,  and  any  other 
personal safety equipment required by the local standards and regulations. 

5.

 

Use  only  appropriate  standard  tools  and  equipment  operated  by  qualified  operators  when  installing,  operating 
and maintaining the product. 

6.

 

Prior to installation, operation, maintenance or any other type of action carried out on the product, read carefully 
the safety, installation and operation instructions of the product. 

7.

 

Please note: 

-

 

Pressurized fluid and/or gas may be discharged from the product without prior warning. Make sure that all products' 

outlet ports are not directed toward electrical elements (pumps) or people. 

8.

 

Always open and close valves slowly and gradually. 

9.

 

Please  note  that  the  maximum  working  pressure  indicated  at  the  product’s  specifications  table  doesn't  include 
pressure  changes  caused  by  water  hammer  and  pressure  surge  effects.  Use  the  product  only  according  to  its 
designated pressure rate specifications. 

10.

 

Use the product only for its intended use as designed by A.R.I. Any misuse of the product may lead to undesired 
damages  and  may  affect  your  warranty  coverage.  Please  consult  with  A.R.I.  prior  to  any  non-regular  use  of  this 
product  and  make  no  change  or  modification  to  the  product  without  a  prior  written  consent  to  be  provided  by 
A.R.I. at A.R.I.'s sole discretion. 

11.

 

Please note that A.R.I. shall NOT assume any liability with respect to any damage losses and/or expenses caused to 
any person and/or property  whatsoever unless the product has been duly installed  and thereafter maintained in 
strict  compliance  with  its  designated  maintenance  Instructions  and/or  any  other  installation  and  operation 
manuals provided by A.R.I. for the product and/or applicable ordinances and/or codes. 

 

Handling 

1.

 

Shipping and handling the product must be done in a safe and stable manner and in accordance with the relevant 
standards and regulations. 

2.

 

Storage should be in the original delivery crates or cases. Storage should be off the ground in a clean, dry indoor 
area. 

3.

 

For  lifting  and  positioning  the  product,  use  only  approved  lifting  equipment  operated  by  authorized  employees 
and contractors. 

4.

 

Prior to the installation visually verify that the product was not damaged during shipment to the installation site. 

Содержание Eliptix R-30ME

Страница 1: ...ydraulic control valves The valves are suitable for installation in agriculture water transmission and waterworks systems for irrigation landscape and infrastructure applications The R 30 series has a...

Страница 2: ...tial Set up The Pressure Reducing Application 10 3 OPERATION INSTRUCTIONS 11 4 MAINTENANCE 12 4 1 Periodic Inspection 12 4 2 Storing the valve 12 5 TROUBLESHOOTING 13 6 DISMANTLING AND ASSEMBLING THE...

Страница 3: ...ever whether caused by accessing and or relying upon this Disclaimer and or in any document enclosed hereto including without limitation any links procedures or materials A R I shall NOT assume any li...

Страница 4: ...prior warning Make sure that allproducts outlet portsarenotdirectedtowardelectricalelements pumps orpeople 8 Always open and close valves slowly and gradually 9 Please note that the maximum working pr...

Страница 5: ...lations set for handling this type of fluid 3 Before disconnecting the product from the system and before releasing the residual pressure do NOT loosen or unscrew the product bolts removeanyprotection...

Страница 6: ...ns 2 Make sure that all the tools ladders lifting devices etc used during the maintenance procedures are taken away from the product area and stored 3 Remove grease and fat material residues in order...

Страница 7: ...2 Before installing the valve flush the pipeline to remove scale dirt and other particles that might affect the valve performance 3 Carefully remove the valve from the shipping package Unload all val...

Страница 8: ...lve it is recommended to install the following valves Isolation valves upstream and downstream of the control valve 2 2A Air valves upstream and downstream of the control valve 5 3 Close the 3 way sel...

Страница 9: ...fittings if necessary 4 For Normally Open Valve Energize the solenoid 4 use the PLC s or the Controller s HMI screen 5 Turn the 3 way selector 3 to its AUTO position 6 For Normally Open Valve De ener...

Страница 10: ...ergized water from the valve s upstream port flows into the control chamber and the valve closes When the solenoid is de energized water from the control chamber is released to the atmosphere and the...

Страница 11: ...To manually open the valve turn the manual 3 way selector 3 to its OPEN position To manually close the valve turn the manual 3 way selector 3 to its CLOSE 2 To maintain downstream preset pressure open...

Страница 12: ...tenance 4 1 Periodic Inspection 1 Every 6 months visually inspect the valve s diaphragm for any tears 2 Every 12 months inspect the valve s operation and clean the Finger Filter 3 Check the downstream...

Страница 13: ...the problem continues turn off the water supply to the valve Remove the bonnet and diaphragm remove the foreign object and check that the diaphragm body and cover are not damaged 2 The Diaphragm is d...

Страница 14: ...d ring at the other 20 mm spanner open at one end and ring at the other 24 mm spanner open at one end and ring at the other 2 Release Pressure Make sure that the water supply to the valve is switched...

Страница 15: ...Disassembling the valve 1 Using a 24mm spanner release the 4 bolts of the valve s bonnet in a diagonal manner A D 2 Un screw the bonnet s bolts E F and remove the bonnet from the valve s body G H 1 1...

Страница 16: ...the valve s diaphragm K L 6 4 Cleaning the Finger Filter 1 Disassemble and clean the finger filter using a 20mm spanner release the upstream 2 way manual valve A B Then using a 19mm spanner release th...

Страница 17: ...nd tightened in all directions parallel to the valve s body 6 6 Reassembling the Control loop 1 Make sure that all the control loop components are in good condition and clean 2 Clean the control tubin...

Страница 18: ...R 30 ME 7 DIMENSIONAL DRAWING...

Страница 19: ...R 30 ME 8 SOLENOIDS DATASHEETS...

Страница 20: ...R 30 ME...

Страница 21: ...le nor does this warranty extended to any consequential or incidental damages or expenses of any kind or nature regardless of the nature thereof including without limitation injury to persons or prope...

Отзывы: