![Argus PiCUS TMS 3 Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/argus/picus-tms-3/picus-tms-3_applications-manual_2969446014.webp)
PiCUS TMS 3 manual
14
www.argus-electronic.de
5.1.1 Controlling the maximum number of PiCUS TMS 3
The TMS 3 App allows setting the maximum number of PiCUS TMS 3 to which it might connect
simultaneously. The default setting is 2. This means that the TMS 3 App can connect to a maximum of
2 active PiCUS TMS 3 regardless of the mobile phones capabilities.
This setting can be changed as follows:
1. Start the TMS 3 App.
2. Click the toolbar in the upper right corner.
3. Click
SETTINGS
the view changes to the settings page.
4. Choose
MAX. NUMBER OF SENSORS
.
5. The button
ACCEPT
saves the new value
it is now displayed green.
If the set value is higher than what the mobile phone’s hardware is capable of handling, the update
process in the TMS 3 App may take a very long time and the connection attempts with the PiCUS TMS
3 will most likely fail. If the phones capabilities are unknown, this should be tested thoroughly.
Set the number of simultaneously allowed PiCUS TMS 3 to its maximum value of 7. Then switch on 7
PiCUS TMS 3 and click
REFRESH
. If the mobile phone is capable of handling that number of device all
PiCUS TMS 3 should connect. If not, reduce the number of allowed sensors and retry establishing a
connection until a value is found where the connection works without fail.
Toolbar
Choose the maximum
number of sensors