background image

AS-8060 
User Guide

 

32 

 

 

 

Enable / disable barcodes 

Enable code39 

 

00221

 

Disable code39 

 

00220 

Code39 ID as m 

0031m 

Enable code39 Full ASCII 
(default) 

 

00231 

Disable code39 Full ASCII 

 

00230 

Disable code39 MOD43 Check 
(default) 

 

00240 

Enable code39 MOD43 Check 

 

00241 

Enable code39 transmit check 

 

00251 

Disable code39 transmit check 

 

00250 

Disable code39 transmit* 
(default) 

 

00280 

Содержание AS-8060

Страница 1: ...AS 8060 Barcode Scanner User Manual http www argox com service argox com Version 1 1 Date Oct 18 2019 ...

Страница 2: ...er there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation betw...

Страница 3: ... iii Note All brands and trademarks are the property of their respective owners Note The specifications contained herein are subject to change without notice 警告使用者 這是甲類的資訊產品 在居住的環境中使用時 可 能會造成射頻干擾 在這種情況下 使用者會被要 求採取某些適當的對策 ...

Страница 4: ...rsion information setting code 6 Interface mode setting code 7 Scan mode setting code 8 Sound setting code 8 Character delete insert replacement setting 9 Serial port setting 12 Normal function setting code 14 Prefix suffix setting 16 Multi language setting code 17 Character table 20 Enable disable barcodes 32 Specifications 56 ...

Страница 5: ...ry The embedded memory saves the settings when the power is turned off Turn off the computer s power before connecting the scanner and then power up the computer once the scanner is fully connected You can change a parameter value in the way described below Scan the appropriate bar codes in this guide These new values replace the standard default values in memory NOTE Most computer monitors allow ...

Страница 6: ...tics Healthcare Feature Rich to make daily work simple and easy 2500 pixels CCD image sensor Scan Speed 270 times sec Max reading resolution 3mil 0 762mm Depth of Field 15 330mm EAN 13mil 0 33mm PCS 90 Drop resistance 1 5 meters onto the concrete Auto sensing presentation mode available ...

Страница 7: ...When you receive your scanner open the package immediately and inspect for shipping damage If you discover any damage contact the shipping company and file a claim Argox is not responsible for any damage incurred during shipping Save all package materials for the shipping company to inspect Note If any item is missing please contact your local dealer ...

Страница 8: ...1 Plug the RJ45 connector into your scanner s RJ45 port until you hear a click 2 Connect the USB connector to your computer 3 Turn on your computer It detects your scanner automatically 4 To test your scanner start a text processing program like Notepad or Microsoft Word Scan a bar code and see if the data can be sent to your computer If it s successful you ll hear a beep and the bar code data sho...

Страница 9: ...Guide 5 How to scan AS 8060 emits a light bar when it is scanning To scan a barcode make sure the aiming beam crosses every bar and space of the barcode This bar needs to cross the bar code horizontally to decode it ...

Страница 10: ...preferences This chapter provides information about how to change controls and settings of your scanner Version information setting code Version custom 000A0 Display internal string custom 000A1 Display serial number custom 000A2 Factory default 000B0 Enable the code setting function 09990 Disable the code setting function 09991 ...

Страница 11: ...uter does not have any serial port you will require a so called virtual COM port driver This virtual COM port driver allows you to assign a virtual COM port connection number to your computer connected via a USB port and enables bidirectional communication between your computer and this scanner To download the USB virtual COM port driver of AS 8060 scanner go to the Argox global website http www a...

Страница 12: ...code Trigger mode default 013300 Continuous scan mode 013304 Presentation mode 02311 Key delay 013302 Single not triggered 013301 Key delay not triggered 013303 Auto flashing 013305 Sound setting code Sound on default 014201 Sound off 014200 ...

Страница 13: ...volume sound 014300 Low volume sound 014301 Buzzer frequency 2731 0145AAA Character delete insert replacement setting Code ID off default 01400 Code ID on 01401 Rear code ID on 01402 Display code front character default 0201x Hide code front blank 0200 SPACE ...

Страница 14: ... a blank key 0202 SP Display characters inside code default 0205 Hide inside code 0204 Disable A replace 0 in code default 020600 Enable A replace 0 in code 02060A Display rear characters default 023300 Hide rear 5 characters 023305 Hide rear 1 characters 023301 Display front characters default 023400 ...

Страница 15: ...cters default 023900 Hide 5 middle characters 023905 Forward start from 4th character 024004 FUNC1 replace with 1 0160049 FUNC2 replace with 2 0161050 FUNC3 replace with 3 0162051 FUNC4 replace with 4 0163054 Disable enter replace default 0182013 Enter replace with 5 0182055 ...

Страница 16: ...600bps 000701 Baud rate 1200bps 000702 Baud rate 2400bps 000703 Baud rate 4800bps 000704 Baud rate 9600bps default 000705 Baud rate 19200bps 000706 Baud rate 38400bps 000707 Baud rate 57600bps 000708 Baud rate 115200bps 000709 Serial Port No Check 001200 ...

Страница 17: ...202 Serial port handshake timeout 2s 0013020 Serial port handshake timeout 5s 0013050 Serial port 8 bit data 00080 Serial port 7 bit data 00081 Serial port 1 stop bit 00090 Serial port 2 stop bits 00091 Serial port No parity check 001000 Serial port odd parity check 001001 ...

Страница 18: ...tion setting code Enable upload setting barcodes 02501 Disable upload setting barcodes default 02500 FUNC cast light upon cancel default 01640 Disable change 02510 All uppercase 02511 All lowercase 02512 Uppercase interchange with lowercase 02513 Enable command beep 01411 ...

Страница 19: ...de 15 Disable command beep 01410 Forward image identify default 00161 Reverse image identify 00160 Fastest transmit rate 001500 Medium transmit rate default 001502 Lower transmit rate 001504 Lowest transmit rate 001506 ...

Страница 20: ...213 r n All barcodes rear add ETX 0211 ETX All barcodes front add F2 02160081 All barcodes rear add F2 02110081 Cancel all barcodes rear format character 0210 Add STX before barcodes 0217 STX Cancel all boots before barcodes 0215 Add prefix 02240 Add suffix 02241 ...

Страница 21: ...fix 02220 Clear all suffix 02200 Enter hidden front character mode 02340 Enter hidden rear character mode 02341 Enter hidden middle character mode 02342 Enter the hidden Nth character mode 02343 Multi language setting code English default 0005000 Canada French 0005001 ...

Страница 22: ...lands 0005002 Spain Spanish 0005003 Argentina Latin American 0005004 Brazil Portuguese 0005005 Denmark Danish 0005006 UK English 0005007 Italy Italian142 0005008 France French 0005009 German Germany 0005010 Norway Northern Sami 0005011 ...

Страница 23: ... Finland Swedish Finnish 0005012 Slovak Slovakia 0005013 Portuguesa Portuguese 0005014 Czech Republic Czech 0005015 Belgium Dutch 0005016 Turkey F 0005017 Turkey Q 0005018 Poland Polish214 0005019 Switzerland German French 0005020 ...

Страница 24: ...er Guide 20 Croatia Srb Crt 0005021 Hungary Hungarian 0005022 Japan Japanese 0005023 Russia Russian 0005024 Arabic Egypt 0005025 Character table For adding pre suffix 1001 SOH 1003 ETX 1002 STX 1004 EOT 1006 ACK ...

Страница 25: ...AS 8060 User Guide 21 1005 ENQ 1007 BEL 1009 TAB 1008 Backspace 1010 Line 1012 FF 1011 VT 1013 Enter 1015 SI 1014 SO 1016 DLE 1018 DC2 1017 DC1 ...

Страница 26: ...AS 8060 User Guide 22 1019 DC3 1021 NAK 1020 DC4 1022 SYN 1024 CAN 1023 ETB 1025 EM 1027 ESC 1026 SUB 1028 FS 1030 RS 1029 GS 1031 US 1033 ...

Страница 27: ...AS 8060 User Guide 23 1032 SPACE 1034 1036 1035 1037 1039 1038 1040 1042 1041 1043 1045 1044 ...

Страница 28: ...x 1051 3 Note Used to set address prefix suffix 1050 2 Note Used to set address prefix suffix 1052 4 Note Used to set address prefix suffix 1054 6 Note Used to set address prefix suffix 1053 5 Note Used to set address prefix suffix 1055 7 Note Used to set address prefix suffix 1057 9 Note Used to set address prefix suffix ...

Страница 29: ...AS 8060 User Guide 25 1056 8 Note Used to set address prefix suffix 1058 1060 1059 1061 1063 1062 1064 1066 B 1065 A 1067 C 1069 E 1068 D ...

Страница 30: ...AS 8060 User Guide 26 1070 F 1072 H 1071 G 1073 I 1075 K 1074 J 1076 L 1078 N 1077 M 1079 O 1081 Q 1080 P 1082 R 1084 T ...

Страница 31: ...AS 8060 User Guide 27 1083 S 1085 U 1087 W 1086 V 1088 X 1090 Z 1089 Y 1091 1093 1092 1094 1096 1095 _ ...

Страница 32: ...AS 8060 User Guide 28 1097 a 1099 c 1098 b 1100 d 1102 f 1101 e 1103 g 1105 i 1104 h 1106 j 1108 l 1107 k 1109 m 1111 o ...

Страница 33: ...AS 8060 User Guide 29 1110 n 1112 p 1114 r 1113 q 1115 s 1117 u 1116 t 1118 v 1120 x 1119 w 1121 y 1123 1122 z ...

Страница 34: ...AS 8060 User Guide 30 1124 1126 1125 1127 Delete 1129 F2 1128 F1 1130 F3 1132 F5 1131 F4 1133 F6 1135 F8 1134 F7 1136 F9 1138 F11 ...

Страница 35: ...AS 8060 User Guide 31 1137 F10 1139 F12 1141 HOME 1140 INSERT 1142 Page up 1144 END 1143 Delete 1145 Page down 1147 Left arrow 1146 Right arrow 1148 Down arrow 1149 Up arrow ...

Страница 36: ...9 00220 Code39 ID as m 0031m Enable code39 Full ASCII default 00231 Disable code39 Full ASCII 00230 Disable code39 MOD43 Check default 00240 Enable code39 MOD43 Check 00241 Enable code39 transmit check 00251 Disable code39 transmit check 00250 Disable code39 transmit default 00280 ...

Страница 37: ...acters hiding code32 01961 System characters sending code32 01960 Setting the CODE39 to a min length of 1 Software version available before and after V7 53 003201 Setting the CODE39 to a min length of 2 default Software version available before and after V7 53 003202 Setting the CODE39 to a min length of 3 Software version available before and after V7 53 003203 ...

Страница 38: ... version available after V7 53 00322 Code39 min length 3 Software version available after V7 53 00323 Enable UPC A default 00341 Disable UPC A 00340 UPC A ID as e 0049e Enable UPC A change to EAN 13 00391 Disable UPC A change to EAN 13 default 00390 Transmit UPC A check digit default 00421 No transmit UPC A check digit 00420 ...

Страница 39: ...400 UPC A hide system digit 00401 Enable UPC E default 00351 Disable UPC E 00350 UPC E ID as f 0050f Enable UPC E change to UPCA 00381 Disable UPC E change to UPC A default 00380 UPC E hiding system characters 00431 UPC E sending system characters 00430 ...

Страница 40: ...ck digits 00440 Enable EAN 13 default 00361 Disable EAN 13 00360 EAN 13 ID as d 0051d Transmit EAN 13Check digit default 00461 No transmit EAN 13 check digit 00460 Enable EAN 13 change to ISBN 00481 Disable EAN 13 change to ISBN default 00480 Enable EAN 13 change to ISSN 01501 ...

Страница 41: ...multiple verify 00541 Disable EAN 13 multiple verify default 00540 Enable EAN 8 default 00371 Disable EAN 8 00370 EAN 8 ID as c 0052c EAN 8 transmit check digit default 00571 EAN 8 No transmit check digit 00570 EAN 8 hide system digit 00561 EAN 8 display system digit default 00560 ...

Страница 42: ...pplement 00551 Enable 2 digit 5 digit supplements 00553 Disable supplement default 00550 Enable code93 default 00621 Disable code93 00620 Code93 ID as i 0066i Enable code93 multiple verify 00681 Disable code93 multiple verify default 00680 Enable Code93 MOD47 default 01901 ...

Страница 43: ...ble code128 default 00691 Disable code128 00690 Code128 ID as a 0081a Disable code128 multiple verify default 00840 Enable code128 multiple verify 00841 Enable codabar default 00851 Disable codabar 00850 Codabar ID as v 0094v Codabar min length 4 008704 ...

Страница 44: ...Enable interleaved 2 of 5 default 00961 Disable interleaved 2 of 5 00960 Interleaved 2 of 5 ID as n 0104n Interleaved 2 of 5 min length 4 009704 Enable Interleaved 2 of 5 ID check 00981 Disable Interleaved 2 of 5 ID check 00980 No transmission of check on Interleaved 2 of 5 ID 00991 Transmission of check on Interleaved 2 of 5 ID 00990 ...

Страница 45: ...isable bank mode 01000 Enable industrial 2 of 5 default 01061 Disable industrial 2 of 5 01060 Industrial 2 of 5 ID as o 01130 Industrial 2 of 5 min length 3 010703 Enable MSI 01151 Disable MSI default 01150 MSI ID as s 0053s MSI min length 4 011804 ...

Страница 46: ...01161 Disable Plessey default 01160 Plessey ID as t 0117t Plessey min length 3 011903 Enable code11 default 01261 Disable code11 01260 code11 ID as u 0131u Code11 min length 4 012804 Code11 auto CK check 01271 Code11 C check default 01272 ...

Страница 47: ...nable Matrix 25 default 01461 Disable Matrix 25 01460 Matrix 25 ID as q 00147q Matrix 25 min length 2 014802 Matrix 25 min length 3 014803 Enable postal 25 01571 Disable postal 25 default 01570 Postal 25 ID as r 0158r Postal 25 min length 5 015905 ...

Страница 48: ...5 01871 Disable aerial 25 default 01870 Aerial 25 ID as p 0188p Aerial 25 min length 7 018907 All EAN change to ISSN 02371 Disable EAN change to ISSN default 02370 All EAN change to ISBN 02361 Disable EAN change to ISBN default 02360 Enable digital keyboard mode 02581 ...

Страница 49: ...70 GS1 Omni ID as j 0168j Enable GS1 Limited 01771 Disable GS1 Limited default 01770 GS1 Limited ID as k 0178k Note The setting code type is code128 When generating a barcode you must add 3 before the barcode ie 3 required barcode The ASCll codes in this table are all decimal For the hexadecimal please refer to the attached table 2 ...

Страница 50: ...nd 0221 stands for one common pre suffix code where the value of X represents the added character and this X is a binary For example to add a common pre suffix code A the setting code is 0221A which means that the suffix code A is added to all barcodes Input the following data in the software The setting code is 0223A which means that all barcodes are added with the first code A Input the followin...

Страница 51: ...acter after the bar code and then add Enter the setting code is 0213 r the suffix code is 0212 non accumulative 0213 accumulative 2 times and 0211 accumulative 3 times 3 Adding an exclusive suffix code A certain type of barcode needs to be added with an exclusive suffix code For example the Code 128 codes needs to be followed by the letter A there are two ways to achieve 1 0211 0141 2 0212 AA If y...

Страница 52: ...seconds to automatically shut down the setting code is 0310015 If it takes 5 minutes to automatically shut down the setting code is 0310015 Sleep time limit 42 minutes and 47 seconds 2 Button timeout setting code 0235nn If the button timeout is 4S the setting code is 023540 3 Introduction to the character hiding The hidden suffix character setting code is 0233nn To hide the suffix 5 characters the...

Страница 53: ...racter 456 then the setting codes are 023903 to hidden 3 middle characters and 024003 to begin hiding after the third character and they can be used together to achieve the function and obtain 123789 Code table 1 for barcode types 00 All A 01 code128 C 03 EAN8 D 04 EAN13 E 05 UPCA F 06 UPCE I 09 CODE93 J 0A GS1 OMNI K 0B GS1 LIMI M 0D CODE39 N 0E Interleaved 2 of 5 O 0F Industrial 2 of 5 P 10 Aeri...

Страница 54: ...88 F10 0x89 F11 0x8A F12 0x8B Insert 0x8C Home 0x8D Page up 0x8E Page down 0x91 Delete 0x8F End 0x90 Right 0x92 Left 0x93 Down 0x94 Up 0x95 If CODE93 is added with the STX prefix code according to the STX ASCII value that is 0x02 then the content of the setting code that should be printed is as shown below Tip 1 ASCII F3 0 2 1 6 I STX Binary F3 0x30 0x32 0x31 0x37 0x49 0x02 Setting barcode ...

Страница 55: ... on the previous page home key value is 0x8D ASCII Table 2 Decimal Hexadecimal Character 0 0 Null 1 1 Header start 2 2 Text start 3 3 Text end 4 4 Transmission end 5 5 Query 6 6 Confirmation 7 7 Ring 8 8 backspace 9 9 Level positioning character 10 0A Line feed new line 11 0B Vertical positioning character 12 0C Form feed new page 13 0D Enter 14 0E Shift out 15 0F Shift in 32 20 space 33 21 34 22 ...

Страница 56: ...Decimal Hexadecimal Character 35 23 36 24 37 25 38 26 39 27 40 28 41 29 42 2A 43 2B 44 2C 45 2D 46 2E 47 2F 48 30 0 49 31 1 50 32 2 51 33 3 52 34 4 53 35 5 54 36 6 55 37 7 56 38 8 57 39 9 58 3A 59 3B 60 3C 61 3D 62 3E 63 3F ...

Страница 57: ... J 75 4B K 76 4C L 77 4D M 78 4E N 79 4F O Decimal Hexadecimal Character 16 10 Data link translation 17 11 Device control 1 18 12 Device control 2 19 13 Device control 3 20 14 Device control 4 21 15 Reverse confirmation 22 16 Synchronous idle 23 17 Transmission block end 24 18 Cancel 25 19 Media end 26 1A Interchange 27 1B Translation ...

Страница 58: ...arator 29 1D Group separator 30 1E Record separator 31 1F Unit separator 80 50 P 81 51 Q 82 52 R 83 53 S 84 54 T 85 55 U 86 56 V 87 57 w 88 58 X 89 59 Y 90 5A Z 91 5B 92 5C 93 5D 94 5E 95 5F _ 96 60 97 61 a 98 62 b 99 63 c 100 64 d 101 65 e 102 66 f 103 67 g 104 68 h ...

Страница 59: ...imal Hexadecimal Character 105 69 i 106 6A j 107 6B k 108 6C l 109 6D m 110 6E n 111 6F o 112 70 p 113 71 q 114 72 r 115 73 s 116 74 t 117 75 u 118 76 v 119 77 w 120 78 x 121 79 y 122 7A z 123 7B 124 7C 125 7D 126 7E 127 7F DEL ...

Страница 60: ...g Power DC5V 1 Trigger Switch 1 000 000 cycles Light Source RED LED 620nm 630nm Interface USB HID USB Virtual COM Indication LED Beeper Performance Resolution 3mil 0 76mm Scan Rate 270 time s Scan Angle Yaw 55 Rotation 30 Pitch 65 Environment Light strength 70 000 Lux Temperature Operating temp 20 C to 50 C Storage temp 40 C to 70 C Humidity 5 to 95 Non condensing Drop Withstands multiple times 1 ...

Отзывы: