1
1 - 28
Capacity [minimum~maximum]
kW
BTU/h
Air circulation (Hi/Me/Lo)
m3/h
Moisture removal (High)
Liters/h
External static pressure (High)
Pa(mmAq)
Voltage rating
V
Available voltage range
V
Running amperes*
A
Max–Running amperes**
A
Power input
kW
C.O.P
W/W
Max. Starting amperes
A
Controls/Thermostat control
Timer
Fan speeds Indoor/Outdoor
Airflow direction (Indoor)
Air filter
Remote controller (Option)
Refrigerant control
Drain pump (Drain connection)
Compressor
Operation sound
Indoor - Hi/Me/Lo
dB - A
Outdoor - Hi
dB - A
Color (Approximate value)
Indoor
Outdoor
REFRIGERANT TUBING
Limit of tubing length
m (ft.)
Limit of tubing length at shipment
m (ft.)
Limit of elevation difference
m (ft.)
between the two units
Refrigerant tube
Narrow tube
mm (in.)
outer diameter
Wide tube
mm (in.)
Refrigerant amount at shipment
kg
DIMENSIONS & WEIGHT
Unit dimensions
Height
mm (in.)
Width
mm (in.)
Depth
mm (in.)
Package dimensions
Height
mm (in.)
Width
mm (in.)
Depth
mm (in.)
Net weight
kg (lb.)
Shipping weight
kg (lb.)
Shipping volume
m
3
(cu. Ft)
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
Cooling:
Rating conditions (*):
Indoor air temperature 27°C DB/19°C WB, Outdoor air temperature 35°C DB
Full load conditions (**):
Indoor air temperature 32°C DB/23°C WB, Outdoor air temperature 43°C DB
Indoor unit
Outdoor unit
310 (12-7/32)
1,480 (58-9/32)
630 (24-26/32)
358 (14-3/32)
1,671 (65-25/32)
783 (30-26/32)
47 (104)
52
–
Munsell 1Y 8.5/0.5
50 (164)
–
Max.head 50 cm above drain connection (25A , OD32mm)
Rotary(SANYO)
40/37/33, (44/40/37 : using the booster cable)
15.88 (5/8)
R410A - 3.6
52 (115)
–
Field supply
5~30 (16~98)
Outdoor unit is higher than indoor unit : 30 (98)
Outdoor unit is lower than indoor unit : 15 (49)
9.52 (3/8)
4.34 4.36 4.37
2.88 2.87 2.86
20.3
Outdoor Unit AES125PIC
POWER SOURCE
220 - 230 - 240 V/1 phase/50/60 Hz
Cooling
12.5 [2.7~14.0]
42,500 [9,200~48,000]
1,980/1,560/1,320
6.6
ELECTRICAL RATINGS
1015 (39-31/32)
409 (16-3/32)
100 (220)
109 (240)
78 (8.0) : at shipment, 113 (11.5) : using the booster cable
220
230
340 (13-3 /8)
1330 (52-3 /8)
MODEL No. Indoor Unit ADS125PH
Wired : REM HW Wireless : REM HL
PERFORMANCE
240
198 - 264
22.0 21.1
FEATURES
Microprocessor/I.C.thermostat
1230 (48- 7/16)
940 (37)
0.468 (16.5)
0.552 (19.5)
ON/OFF 72-hours
3 and Automatic control/Variable
1-1. Unit Specifications
Concealed-Duct Type ADS125PH / AES125PIC
04-163 Sanyo-1_p30-61 7/28/04 5:46 PM Page 60
Содержание ACS100PH
Страница 95: ...3 3 2 3 1 Indoor Units Wall Mounted Type AWS36PH Electric Wiring Diagram ...
Страница 96: ...3 3 3 3 1 Indoor Units Wall Mounted Type AWS36PH Schematic Diagram ...
Страница 97: ...3 3 4 3 1 Indoor Units Wall Mounted Type AWS71PH Electric Wiring Diagram ...
Страница 98: ...3 3 5 3 1 Indoor Units Wall Mounted Type AWS71PH Schematic Diagram ...
Страница 99: ...3 3 6 3 2 Outdoor Units Electric Wiring Diagram AES71PIC ...
Страница 100: ...3 3 7 3 2 Outdoor Units Schematic Diagram AES71PIC ...
Страница 101: ...3 3 8 3 2 Outdoor Units Electric Wiring Diagram AES71PIH ...
Страница 102: ...3 3 9 3 2 Outdoor Units Schematic Diagram AES71PIH ...
Страница 103: ...3 3 10 3 2 Outdoor Units Electric Wiring Diagram AES100PIC ...
Страница 104: ...3 3 11 3 2 Outdoor Units Schematic Diagram AES100PIC ...
Страница 105: ...3 3 12 3 2 Outdoor Units Electric Wiring Diagram AES100PIH ...
Страница 106: ...3 3 13 3 2 Outdoor Units Schematic Diagram AES100PIH ...
Страница 107: ...3 3 14 3 2 Outdoor Units Electric Wiring Diagram AES125PIC ...
Страница 108: ...3 3 15 3 2 Outdoor Units Schematic Diagram AES125PIC ...
Страница 109: ...3 3 16 3 2 Outdoor Units Electric Wiring Diagram AES125PIH ...
Страница 110: ...3 3 17 3 2 Outdoor Units Schematic Diagram AES125PIH ...