EL7-I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04/2021
Page 11
www.argo-hytos.com
Logging in to the application:
After clicking on the selected unit, a login window for entering the password will be displayed.
The default password was set to
1234
by the manufacturer.
The password can be changed in the application, see. Changing the password on page 17.
The forgotten password can be deleated by holding the “Configuation button” on
the front panel of the electronics. The button must be held for 10s or more until the
blue LED flashes, the password is then set to 1234 again
See page 5 for access and location of the „
Configuration button
“.
After clicking
Login
, a connection will be made to the electronics, which will no longer be visible
to other devices and it will not be possible to connect to it from another device. The blue LED will
be lit continuously.
Pozor!
The button is located directly on the electronics motherboard, use a non-conductive
object to press the button. Any contact of a conductive object with the electronics
board around the button, can damage or destroy the electronics.
Pozor!
By removing the lid, the electronics lose primary protection against moisture and dirt,
it is necessary to ensure that neither mositure nor dirt get inside during use of the
“
Configuration button
“. Leave the lid removed only for the necessary length of time
and refit as soon as possible.
Pozor!
There is a seal around the perimeter of the lid and under the screw, which must remain
intact after removal and return of the lid on the electronics and the rim surfaces must
be clean. Otherwise, the seal will not perform its function properly, moisture and dirt
may enter the electronics and cause destruction.
Status of electronics:
The information window gives a basic overview of the electronics status, the level of the command
signal, the current and required current to the coils, the supply voltage, the processor temperature and
the running time of the electronics. If the limits are exceeded, an error message describing the source
and cause of the error will be displayed. When the error condition is cleared, it automatically returns
to the operating state, the errors do not need to be acknowledged or related in any way. See possible
error conditions. page 19.
The application enables control of the connected valve or directional control valve directly without
changing the control voltage. After activation, it is possible to change the command signal in the
range of 0 – 100 for one coil, or -100 % - 100 % for others.
During manual control, the electronics do not respond to
the
input
command
signal.
Manual control is deactivated by a switch in the application,
or is automatically cancelled when the application is closed
or the Bluetooth connection is interrupted.
Manual control:
Caution!
All the necessary safety guidelines must be observed before commissioning manual control. At the same time, the
directional control valve stops responding to the input command signal and it is necessary to ensure that unintentional or
dangerous behavior of the device does not occur when switching.
Содержание EL7-I Series
Страница 2: ...EL7 I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04 2021 Page 2 www argo hytos com...
Страница 22: ...EL7 I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04 2021 Page 22 www argo hytos com...
Страница 42: ...EL7 I_Pokyny_Instructions_Hinweise_19151_1en_de_cz_04 2021 Page 42 www argo hytos com...