OPERATING INSTRUCTIONS: 
 
POWER ON/OFF: 
 

The  receiver  is  powered  on  and  off  by  inserting  the  headphone  plug  into  the  headphone  jack.  When  you  plug  the 
headphones  in,  the  receiver  will  turn  on.  When  you  unplug  the  headphones,  the  receiver  will  turn  off  after  a  few 
seconds. 
 

SETTING UP AND PROGRAMMING THE CHANNELS: 
 

The  receiver  has  six  “groups”  of  frequencies  that  are  pre-programmed  to  channel  numbers  that  correspond  to  the 
frequency/channel pairs used by the various entertainment/fitness equipment manufacturers.  These “groups” allow 
you  to  directly  interface  with  transmitters  and  receivers  from  other  manufacturers

.    The  “groups”  match  up  to  the 

manufacturers as follows: 
 

Group 1 

– ARG’s Custom Channels 

Group 2 

– User programmable w/auto-scanning feature 

Group 3 

– Compatible with Cardio Theater (XTV-9T) products 

Group 4 

– Compatible with Cardio Theater (XTV-9TM) products 

Group 5 

– Compatible with MYE/Fantaay/True products 

Group 6 

– Compatible with BVe/Broadcast Vision products 

The  receiver  comes  preset  to  Group  1,  the  ARG  custom  channel  grouping.    If  you  need  to  change  the 
group/frequencies  to  be  compatible  with 

other  manufacturer’s  equipment,  you  can  change  the  group  number  as 

follows: 
 

1. 

Press and hold the “VOLUME UP” and “MEMO” buttons at the same time for about four seconds until 
the lock icon disappears and the small group number shows in the center of the display. 

2. 

Using  the  “MUTE”  button,  choose  the  group  number  of  the  frequency/channel  pairs  you  wish  to  use 
based on the list above. 

3. 

The “CHANNEL UP” and “CHANNEL DOWN” buttons allow you to view the channels available in that 
specific group.  Choose the channels 

you are using by pressing the “MEMO” button to enable/disable 

the channels in the group.  The channels with the word “MEMORY” showing in the display are enabled 
and  vice  versa.    For  example:  if  you  have  three  TV’s  each  one  with  its  own  transmitter,  you  would 
enable channels 1, 2, and 3. 

4. 

Return to normal “user” mode by pressing and holding the “VOLUME UP” and “MEMO” buttons together 
for four seconds once again. 

 
If you are going to select your own frequencies/channel pairs, you can do so by first using the previous process to set 
the receiver to “group 2”.  Leave the receiver in the programming mode to set-up your own frequency/channel pairs 
that correspond to the frequencies you have set your transmitters to broadcast on.   At this point you MUST have the 
re

ceiver perform an “auto-scan” to determine what frequencies are being used by the devices in your facility.  The 

receiver has to scan through all of the frequencies in the 900MHz bandwidth to “find” the frequencies that are in use 
at  your  location.    Before 

going  through  the  “auto-scan”  procedure,  make  sure  that  ALL  of  the  transmitters  in  your 

facility  are:  a)  powered  on,  b)  connected  to  a  signal  source,  c)  set  to  and  broadcasting  on  your  desired  broadcast 
frequencies. 
 
Now, perform the “auto-scan” function as follows:  
 

1. 

Double check to make sure the receiver is in the “user” mode 

2. 

Press and hold the MUTE and SCAN buttons for five seconds.  This will put the receiver into “setting mode” 

3.   Start  the  auto-

scan”  process  by  pressing  the  “SCAN”  button  once.  The  receiver  will  now  scan  ALL  the 

frequencies in the 900MHz bandwidth. (902MHZ to 928MHz) Every time the receiver detects a signal, it will 
store that frequency to a list of used frequencies that you will pair with channel numbers later. It takes about 
two minutes for the receiver to complete the auto-scan process.  

 
 
 
 
 
 
 

Содержание ARG-OM-012

Страница 1: ... Group Inc 405 Main Ave W Unit 4G West Fargo ND 58078 2013 Audio Resource Group Inc All Rights Reserved www argaudio com Fitness Entertainment Solutions 900 MHz Analog Receiver Manual and User Guide ARG OM 012 Rev B ...

Страница 2: ...d the bar on the cardio machine at the predetermined location Pull the ties tightly around the bar so the receiver does not move or rotate Be careful not to over tighten the ties to avoid cracking the mounting cleat or case of the receiver Trim off the excess ends of the cable ties 4 Connect the power cable to the receiver The receiver can be powered by either a CSAFE power outlet on the cardio ma...

Страница 3: ...nnels you are using by pressing the MEMO button to enable disable the channels in the group The channels with the word MEMORY showing in the display are enabled and vice versa For example if you have three TV s each one with its own transmitter you would enable channels 1 2 and 3 4 Return to normal user mode by pressing and holding the VOLUME UP and MEMO buttons together for four seconds once agai...

Страница 4: ... reappear and your receiver will now be in the normal operating mode Note The receiver will only save up to 64 frequencies in the memory and will stop auto scanning when it collects the 64th frequency in the found list If the receiver does not find all of the frequencies your transmitters are broadcasting or if you are in an area with excessive noise or interference you can adjust the scanning sen...

Страница 5: ...efects discovered within the warranty period and notification to ARG must be given within 30 days after the date of discover of any nonconformity Parts repaired or replaced under the terms of this warranty will be warranted for the remainder of the original warranty period only Product that fails after the warranty period will be repaired or replaced at the current part and labor pricing after ins...

Отзывы: