BIOS CONFIGURATION
84
3.7.5.11 Controller Fan Detection
The ARC-1880ix series incorporate one big passive heatsink that
allows the hot devices such as a ROC and expander chip to keep
cool. In addition, newer systems already have enough air flow
blowing over the controller. The big passive heat sink has pro-
vided enough adequate cooling for ROC and expander chip.
The “Controller Fan Detection” function is available in the firm
-
ware for detecting the cooling fan function on the ROC which
uses the active cooling fan on the ARC-1882i/x/LP/ixl-8/ixl-12
low profile board. When using the passive heatsink on the con
-
troller, disable the “Controller Fan Detection” function through
this McBIOS RAID manager setting. The following screen shot
shows how to change the McBIOS RAID manager setting to dis-
able the warning beeper function.
(This function is not avail-
able in the web browser setting.
I/O Port Addr : 28000000h, F2(Tab): Select Controller, F10: Reboot System
ArrowKey Or AZ:Move Cursor, Enter: Select, ESC: Escape, L:Line Draw, X: Redraw
Areca Technology Corporation RAID Controller
Main Menu
Quick Volume/Raid Setup
Raid Set Function
Volume Set Function
Physical Drives
Raid System Function
Hdd Power Management
Ethernet Configuration
View System Events
Clear Event Buffer
Hardware Monitor
System information
Raid System Function
Raid System Function
Mute The Alert Beeper
Alert Beeper Setting
Change Password
JBOD/RAID Function
Background Task Priority
SATA NCQ Support
HDD Read Ahead Cache
Volume Data Read Ahead
Hdd Queue Depth Setting
Empty HDD Slot LED
Controller Fan Detection
Auto Activate Raid Set
Disk Write Cache Mode
Capacity Truncation
Controller Fan Dectection
Controller Fan Detection
Enabled
Disabled
3.7.5.12 Auto Activate Raid Set
When some of the disk drives are removed in power off state
or boot up stage, the RAID set state will change to “Incomplete
State”. But if a user wants to automatically continue to work
while the 6Gb/s SAS RAID controller is powered on, then user
can set the “Auto Activate Raid Set” option to “Enabled”. The
RAID state will change to “Degraded Mode” while it powers on.