HARDWARE INSTALLATION
37
Figure 2-18, Activity/Fault LED serial bus connector connected
between 6Gb/s SAS RAID controller & 4 SATA HDD backplane.
PIN
Description
PIN
Description
1
Power (+5V)
2
GND
3
LCD Module Interrupt
4
Protect Key
5
LCD Module Serial Data
6
Fault/Activity Clock
7
Fault/Activity Serial Data
8
LCD Module Clock
The following picture and table is the serial bus signal name de-
scription for LCD & fault/activity LED.
B: Areca Serial Bus Connector
You can also connect the Areca interface to a proprietary SAS/
SATA backplane enclosure. This can reduce the number of activity
LED and/or fault LED cables. The I
2
C interface can also cascade to
another SAS/SATA backplane enclosure for the additional channel
status display.
Areca serial bus also supports SES (SCSI Enclosure Services)
over I
2
C over internal I
2
C backplane cable. The backplane
cable can connect the I2C signal from Areca controller to the
backplane using IPMI-style I
2
C 3-pin connector. It means you
link I
2
C cable into back plane, and let back plane LED indicate
HardDisk fail status.
Содержание ARC-1880 Series