AREBOS 4260627424252 Скачать руководство пользователя страница 12

User’s Manual

 

 A

REBO

S Infrared heater 2500 W with remote control 

 

12 

 
 

7.

 

Cleaning, maintenance and service 

7.1 Maintenance 

 

It is very important to perform careful and regular maintenance of the device in accordance 
with the recommendations made in this manual so that it can run efficiently for a long time. 
In case there is a problem with your heater, please contact a qualified specialist. 

 

Before maintenance or cleaning work, the device must be disconnected from the electricity 
grid. 

 

Once a month, a check should be made as to whether there is any potential contamination. 

 

If the infrared heater is dirty, careful cleaning should be performed. See point Cleaning. 

 

Of course, the above checks are always dependent on how much pollution is present at the 
respective location of the device. 

 

The reflector and the tube should also be visually inspected for deformation or damage. In 
the case of conspicuous deformations or glass breakage, please contact a qualified specialist 
to take the necessary steps. 

 

The power cord and plug must also be checked while the unit is being cleaned. If the power 
cord or plug shows any deformation or damage, please contact a qualified professional 
immediately. 

7.2 Cleaning 

 

Attention! Regular and thorough cleaning ensures longevity and optimum performance. 

 

The unit must be switched off and the power cord disconnected from the circuit. In addition, 
it should cool sufficiently before cleaning. 

 

If the tube is dirty, clean it with dry compressed air without removing the protective grid. 
Do not attempt to clean the device using solvents or other flammable liquids. (This can cause 
an electric shock or fire). Also, do not use a steam cleaner. 

 

Clean the outside surface of the unit with a soft cotton cloth, microfiber cloth or a soft brush. 

 

Do not use corrosive cleaning agents or solvents to clean the infrared heater. These can 
damage the surface and components. 

 

Turn on the unit again when it is completely dry and clean. 

 

 

If the device is to be stored for longer, cover it with a protective cover to avoid dust on the 
device and sensitive points. Always disconnect the power plug and switch off the power! 

7.3 Exemplary cleaning of the reflector 

 

Disconnect the power adapter cable from the electrical outlet.

 

 

Remove the heater from the safety bar.

 

 

Remove hood (6) as shown in the picture 

 

Take out the front grid wire through the inlets on the frame using a slotted screwdriver. 

 

Содержание 4260627424252

Страница 1: ...W with remote control 1 Infrared heater 2500 W with remote control AR HE HS2500FB WR B product can differ depending on variety Please follow all security measures in this user s manual to ensure a se...

Страница 2: ...1 Maintenance 12 7 2 Cleaning 12 7 3 Exemplary cleaning of the reflector 12 7 4 Service and repair 13 7 5 Change bulb Fehler Textmarke nicht definiert 8 Troubleshooting 16 9 Disposal Instruction 17 9...

Страница 3: ...mage the device and the power main Power cord must not be left on the hot body of the device or near it If the device is not used moved to another location cleaned or calibrated for an extended period...

Страница 4: ...Device must be unplugged before cleaning Do not clean your device with a steam cleaner Children should be supervised to ensure that they do not play with the appliance Flame protector does not provid...

Страница 5: ...extiles any other materials living organisms and other equipment Note No vertical mounting possible picture is only for distance clarification 1 4 Distances to the bathtub sink or other sanitary facil...

Страница 6: ...7368 4260627424252 Power 2500 W 2500 W Material Aluminium Aluminium Voltage AC 220 240 V AC 220 240 V Frequency 50 Hz 50 Hz Cable length 2 m 1 8 m Protection class I I Protection degree IP20 IP20 Heat...

Страница 7: ...taining acids steams explosive or flammable gases Procedure Loosen the fixed knob on the pipe place the product holder on the pipe component as shown 5 2 Wall mounting Hints Attention The device must...

Страница 8: ...fasteners at the appropriate distance on the wall parallel to the floor at least 71 in 1 80 m from the floor and at least 29 5 in 0 75 m from the ceiling Join the brackets on the heater with the brac...

Страница 9: ...n to select the power level The P 0 indicator appears on the screen and the indicator flashes three times to indicate that the unit is in standby mode The P1 indicator appears on the screen and flashe...

Страница 10: ...ndby If you press the timer button in standby mode you can set the time from 1 to 24 hours on the device After setting the time the indicator lights up which indicates that the unit has been selected...

Страница 11: ...a power failure the heater will start to operate in standby mode After each command a tone beeps 1 ON OFF Power mode button 2 Timer button 3 Power level indicator 4 LED 6 2 How the remote control work...

Страница 12: ...plug shows any deformation or damage please contact a qualified professional immediately 7 2 Cleaning Attention Regular and thorough cleaning ensures longevity and optimum performance The unit must be...

Страница 13: ...er Make sure the heater does not have these errors Check if the thermostat can be switched on or off Check that the heater is properly connected to the electrical wiring Check the intactness of the el...

Страница 14: ...Infrared heater 2500 W with remote control 14 7 5 Change bulb Disassemble the endcaps by loosening the two screws on each side with the screwdriver Screws Pull out the endcaps and slide the metal cove...

Страница 15: ...REBOS Infrared heater 2500 W with remote control 15 Metal cover Disassemble both holding sheets by loosening the nut next to the sheet with a wrench 7mm and hold against from behind with a screwdriver...

Страница 16: ...ng the one inside the standpipe and the burner head has been correctly inserted Check that the device s switch is in the correct position Make sure that you have followed the instructions in the manua...

Страница 17: ...ge in a retail store or at another collection point near you Addresses of suitable collection points can be obtained from your city or local government Batteries may contain substances that are harmfu...

Страница 18: ...ation not allowed by us this declaration loses its validity Tested acc to Low Voltage Directive 2014 35 EC Electromagnetic Compatibility 2014 30 EC EU Standard EN 60335 2 30 2009 A11 2012 EN 60335 1 2...

Отзывы: