14
Scroll back.
Use the scroll back (rapid count down) effect when
changing from “9” to “0”.
“1” = enable
“0” = disable
15
Red Channel Intensity.
Sets the maximum intensity of the red
channel back light. This will be dimmed according to the display
dimming.
Default: 255
Max: 255
Min: 0
16
Green Channel Intensity.
Sets the maximum intensity of the green
channel back light. This will be dimmed according to the display
dimming.
Default: 255
Max: 255
Min: 0
17
Blue Channel Intensity.
Sets the maximum intensity of the blue
channel back light. This will be dimmed according to the display
dimming.
Default: 255
Max: 255
Min: 0
18
Current case temperature.
Show the current temperature inside
the case (used as part of the temperature compensation for the
clock crystal).
19
Clock version.
Show the clock software version. In this version, will
show “0006”.
20
Digit Test.
Will roll through all digits on all locations to check that
the display is healthy.
Display Blanking Mode
During display blanking mode, the “tick” LED will continue to pulse at low intensity, telling you that the
clock is still running. In order to display the time, just press the button, and the time will be displayed.
If you want to enable the display for the rest of the day, do a long press of the button.
Tube Healing Mode
After a long period of time, tube filaments which are not often used (e.g. the “9” on the tens of hours or
minutes) can get dim, despite the ACP that is regularly done.
If you make a “super-long” press of the button (more than 8 seconds), the clock will enter filament healing
mode. All the power will be placed through a single filament of a single digit to clean it. A short press will
change the selected filament.
Another super-long press or cycling through all the filaments will return the clock to normal.
Caution!
Don't leave a single filament in this state for an extended period of time. It is a harsh process,
and may damage the tube if you leave it in this mode for too long. Normally a few minutes will restore the
cathode digit.
Factory Reset
To reset the clock back to initial settings, hold down the button while powering on and hold for at least 3
seconds. The “tick” LED will flash 10 times to signal that the reset has been done.
Everything will be reset back to the factory default state.
Содержание Nixie Clock v6
Страница 7: ...Schematic Below is the schematic for the clock...
Страница 9: ...Construction Kit Contents When you unpack the kit you should find the following contents...
Страница 12: ...At the end of the low voltage circuit build your board should look like this Low Voltage Circuit...
Страница 16: ...At the end of the high voltage circuit build your board should look like this High Voltage Circuit...
Страница 20: ...After you have installed the Anode controls that part of the board should look this...
Страница 24: ...The wiring for the tubes is this...