UE CONFORMITY DECLARATION

The manufacturer:

 

ARDETEM-SFERE

 

Route de Brindas

 

Parc d’activité d’Arbora n°2

 

69510 Soucieu en Jarrest

 

France

declares that the following products:

 

Name: Measure concentrator

 

Type: 

TPIs 2T

comply with the following directives and standards:

The EMC Directive 2014/30/UE

 

EN 61326-1 : 2013

The Low Voltage Directive 2014/35/UE

 

EN 61010-1 : 2011

The ATEX directive 2014/34/UE

 

EN 60079-0 : 2011  EN 60079-15 : 2010

Soucieu en Jarrest, February 14, 2017

 

Jacques Huguet

 

Signature of the Manager

This appliance has to be installed in an environment defined in pollution 

degree 2 / Overvoltage category II or better for a max. altitude of 2000 m.

Before any installation or maintenance work, make sure the power supply 

of the instrument is cut.

This symbole indicates that the module is protected by a double or 

reinforced isolation.

The person who has designed the system (electrical installation including 

the instrument) is sole responsable for the safety and must make sure it 

has been designed according to the current safety standards.

This appliance contains electronic components and 

should not be disposed of with the domestic waste.

It should be collected with the WEEE (Waste Elec-

trical and Electronic Equipment), according to the 

current regulation.

The instrument may be connected to dangerous electrical 

voltages.

It must be mounted, connected and implemented respecting 

the current specific regulations, by a qualified technician, trai-

ned to the safety regulations, who will have read this manual.

Содержание TPIs 2T

Страница 1: ...IQUES INSTRUMENTATIONS AUTOMATISME Route de Brindas Parc d activité d Arbora N 2 69510 Soucieu en Jarrest FRANCE Tél 04 72 31 31 30 Fax 04 72 31 31 31 Tel Intern 33 4 72 31 31 30 Fax Intern 33 4 72 31 31 31 http www ardetem com e mail info ardetem com MODULE OF 2 LOGIC INPUTS TPIs 2T User handbook version 02 02 Software SlimSet ...

Страница 2: ...p1 Summary UE conformity declaration p2 1 INTRODUCTION p3 1 1 General features p3 1 2 Features of the inputs p3 2 CONFIGURATION OF THE NETWORK p4 3 DIMENSIONS MOUNTING p5 4 CONNECTINGS p7 ...

Страница 3: ...Before any installation or maintenance work make sure the power supply of the instrument is cut This symbole indicates that the module is protected by a double or reinforced isolation The person who has designed the system electrical installation including the instrument is sole responsable for the safety and must make sure it has been designed according to the current safety standards This applia...

Страница 4: ...ture 25 C to 70 C Storage temperature 40 C to 85 C Power supply 16 8 to 31 2 Vdc Max power draw 0 7W Max internal dissipation 0 5W Galvanic partition 2 5kV 50Hz 1mn between supply logic inputs µUSB logic inputs not insulated from each other Listed Installation in ATEX IECEx area 2 Installation in division 2 cFMus Compliance with standards Directive EMC 2004 108 CE EN 61326 1 Directive LV 2014 35 U...

Страница 5: ...bus the most on the left or the most on the right Click on communication with the devices and then on add the connected device to the architecture The instrument will be recognized and the software will request its position within the architecture Enter it and do the same for all the instruments of the bus 2 Then choose the instrument which will be the master TPIs or TPIvM and programme it as mast...

Страница 6: ...2 5mm2 14 AWG Protection case terminals IP20 Mounting in switchbox latching on symmetrical DIN rail with footing for the distribution of the 24Vdc power supply and the communication signals Instructions for assembling on 35mm DIN rail according to EN 60715 Assembling of the footings on the rail BEWARE The polarization tongue is at the bottom Assembling of the footings before mounting on DIN rail M...

Страница 7: ...mum de type IP54 Le câble USB ne doit être inséré ou retiré que si l appareil a été mis hors ten sion ou si la zone est sûre Le convertisseur ne doit être déconnecté de son embase rail DIN que si l alimentation du rail a été mise hors tension ou si la zone est sûre L installation doit être réalisée selon le Canadian Electrical Code Partie 1 pour le Canada et le National Electrical Code NFPA 70 pou...

Страница 8: ...p7 4 CONNECTINGS TPIs 2T 8 7 6 5 A B C D E communication 24VDC 30 1 2 3 4 contact 2 0V 5V logic 2 namur 2 contact 1 0V 5V logic 1 namur 1 NPN 1 NPN 2 PNP 1 PNP 2 LED master LED voltage presence ...

Отзывы: