THREE YEAR LIMITED WARRANTY 
 

              Ardent Energy Ltd. warrants the Model HF85R space heater against defects in material and work-
manship for a period of three (3) years from the date received, with the exception of items listed hereafter 
in the "Exclusions" section. 
              Ardent Energy Ltd., at its option, will replace, repair or cause to be repaired any part found to be 
defective upon inspection by an authorized Ardent Energy Ltd. representative. 
 

EXCLUSIONS

 

1.

Repairs or replacement of part or all of the appliance, necessitated by use of the stove other than for 
normal home use, as directed by the instruction manual. 

2.

Repairs or replacements necessitated by vandalism, neglect, abuse or failure to adequately service 
the appliance, as stated in the instruction manual. 

3.

Repairs or replacements necessitated by work or service not authorized by Ardent Energy Ltd.  

4.

Equipment and accessories not manufactured by Ardent Energy are warranted only to the extent of 
the original manufacturer's warranty. 

5.

Repairs or replacement of motors, fittings, controls, transformers, accessories and so forth. 

6.

Replacement of gaskets and firebrick. 

7.

Repairs necessitated by excessive chimney draft. 

 

LIMITATIONS 
 

1.

All items found to be defective will be replaced or repaired upon return of the defective part to an au-
thorized Ardent Energy Ltd. dealer. 

2.

Any space heater or part thereof that is replaced or serviced during the three year warranty period, 
will be warranted under the terms of that particular limited warranty for a period not exceeding the re-
maining term of the original limited warranty, or six months, whichever is longer. 

3.

This warranty is transferable.  However, proof of date of purchase is required before service or re-
placement of any defective part is performed. 

4.

This Limited Warranty does not apply to damage to the space heater or part thereof, while in transit.  
Any claim of such must be directed to the common carrier.  

5.

If the installation does not conform to local building or fire codes, or in their absence, the installation 
requirements in the instruction manual, any claims are not valid and will not be processed. 

6.

Any shipping charges incurred during a warranty claim will be borne by the space heater owner. 

7.

The remedies set forth herein are exclusive, and the liability of Ardent Energy Ltd. with respect to any 
contract, tort, under any warranty or otherwise shall not exceed the price of the equipment or part on 
which such liability is based. 

To enable us to service any warranty claim as quickly as possible, please fill out and return your warranty card as soon as you receive 
your Ardent Energy space heater. 

Model HF85R Space Heater Warranty 

Содержание HF85R

Страница 1: ...Model HF85R SOLID FUEL SPACE HEATER Box 3637 Smithers BC V0J 2N0 INSTALLATION AND OPERATION INSTRUCTION MANUAL PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Operation Maintenance Installation ...

Страница 2: ...r should be included with your order to assure prompt and accurate service We congratulate you on your choice of the ARDENT ENERGY heating system and may your home fires keep burning Yours truly ARDENT ENERGY Inc J G Hans Duerichen P Eng President June 2001 ver 3 TABLE OF CONTENTS SAFETY INSTRUCTIONS PAGE 3 GENERAL SPECIFICATIONS PAGE 3 OPERATION INSTRUCTIONS PAGE 4 Fuel PAGE 4 The bypass damper P...

Страница 3: ... damper and turn down the draft damper com pletely On thermostat models turn down thermo stat If chimney fire does not die down keep a watch on fire and prepare to vacate the house If needed call the fire department NOTE 1 Establish a routine for the storage of fuel care of wood burner and firing technique Be aware that dur ing mild weather and low heater temperatures more creosote is deposited an...

Страница 4: ...errun then the temperature will stabilize RELOADING 1 Have wood on hand to load firebox 2 Open bypass lever for 30 seconds 3 Open the door SLOWLY Allow the chimney to draw off smoke 4 Load wood 5 Close door and push bypass lever in DO NOT OVER FIRE UNIT BY LEAVING DOOR OPEN EX CEPT TO LIGHT AND TO CHECK FIRE Operation with door ajar voids warranty NOTE Cleanest burning conditions occur when the fu...

Страница 5: ...dicate the center of the chimney 4 Check that the intended location will not interfere with ceil ing joists or rafters before proceeding further 5 Install chimney according to chimney manufacturer s in structions Read section on Chimney and see Diagram 2 Chimney must be a 8 diameter listed chimney suitable for wood burning appliances If an existing masonry chimney is to be used read section under ...

Страница 6: ...he above specifications CHIMNEY TERMINATION Chimneys are required to extend at least 915 mm 3 above the highest point where they pass through the roof of the building and at least 610 mm 2 higher than any portion within ten feet In some cases the chimney must be higher than minimum for enough draft due to unfavorable geometry of the surroundings INSTALLATION OF OPTIONS WALL THERMOSTAT KIT MODEL HC...

Страница 7: ...issipate any excess heat generated by the hot water coil Connection of piping to Range Boiler must be strictly followed as shown in the Diagram The 2 shut off valves must be no smaller than 3 4 inch GATE valves Make certain that the PRV Watts 3L and P TRV Watts 100XL are installed in their respective loca tions and not vice versa Maximum pressure setting is 150 psi Do not use less than 3 4 inch di...

Страница 8: ...RE FOR EASY REFERENCE WHEN ORDERING REPLACEMENT PARTS MODEL ____________________________________________ SERIAL I ___________________________________________ DATE OF INSTALLATION _______________________________ 16 11 10 21 6 1 3 22 8 20 5 12 2 15 13 14 7 4 9 ...

Страница 9: ...be replaced or repaired upon return of the defective part to an au thorized Ardent Energy Ltd dealer 2 Any space heater or part thereof that is replaced or serviced during the three year warranty period will be warranted under the terms of that particular limited warranty for a period not exceeding the re maining term of the original limited warranty or six months whichever is longer 3 This warran...