B-4
INSTALLATION
B-4
SAFETY PRECAUTIONS
ELECTRIC SHOCK can kill.
Only qualified personnel should
perform this installation.
Turn the input power OFF at the
main switch or fuse box before
working on this equipment.
Do not touch electrically live parts or electrode
with skin or wet clothing.
Insulate yourself from work and ground.
Always wear dry insulating gloves.
FUMES AND GASES can be dan-
gerous.
Keep your head out of fumes.
Use ventilation or exhaust to rem-
ove fumes from breathing zone.
WELDING SPARKS can cause fire or
explosion.
Keep flammable material away.
Do not weld on closed containers.
PLEASE SEE ADDITIONAL WARNING INFORMATION
AT THE
FRONT OF THIS OPERATOR’S MANUAL.
SELECT SUITABLE LOCATION
This power source should not be subjected to rain,
nor should any parts of it be submerged in water.
Doing so may cause improper operation as well as
pose a safety hazard. The best practice is to keep the
machine in a dry, sheltered area.
The bottom of machine must always be placed on a
firm, secure, level surface. There is a danger of the
machine toppling over if this precaution is not taken.
Place the welder where clean cooling air can freely circul-
ate in through the rear louvers and out through the front
side. Water, dirt, dust or any foreign material that can be
drawn into the welder should be kept to a minimum. Failure
to observe these precautions can result in excessive
operating temperatures and nuisance shutdowns.
Locate the
arcweld
®
machine away from radio
controlled machinery. Normal operation of the welder may
adversely affect the operation of RF controlled equipment,
which may result in bodily injury or damage to the equipment.
WARNING
CAUTION
INPUT CONNECTIONS
ELECTRIC SHOCK can kill.
Have a qualified electrician install and
service this equipment.
Disconnect input power by removing
plug from receptacle before working
inside machines. Allow machine to sit
for 5 minutes minimum to allow the
power capacitors to discharge before
working inside this equipment.
Do not touch electrically live parts.
INPUT POWER CONNECTION
Check the input voltage, phase, and frequency
supplied to this machine before turning it on.
The allowable input voltage is indicated in the
technical specification section of this manual
and on the rating plate of the machine. Be sure
that the machine is earthed (grounded).
INPUT VOLTAGE
The
arcweld
®
machine is provided with a
240V±10% input voltage, 50/60Hz.
An output guide is provided in the technical
specification section of this manual.
ENGINE DRIVEN GENERATOR
The machine is designed to operate on engine
driven generators as long as the auxiliary can
supply adequate voltage, frequency and power
as indicated in the
“Technical Specification”
Installation Section of this manual. The auxiliary
supply of the generator must also meet the
following conditions:
Frequency:
in the range of 50 and 60 Hz
RMS voltage of the AC waveform:
170-
270V; Out of this range will trigger undervoltage
and overvoltage protections.
Peak voltage max
. 380V (AC)
Generator
Minimum 8kVA
It is important to check these conditions
because many engine driven generators
produce high voltage spikes. Operation of this
machine with engine driven generators not
conforming
to
these
conditions
is
not
recommend and may damage the machine and
is also NOT covered by warranty.