19
When replacing the compressor should start relay and start capacitor also replaced.
Start relay is placed on the compressor’s three terminal legs and clamped.
The voltage is connected to terminals 10 and 14.
The start capacitor is connected to terminals 11 and 13 and clamped.
A relay can be checked with an indicator light as
shown in the sketch maintain end. The relay is usu-
ally ok, when in standing position is not lit, and when
it is lit when the relay is upside down.
The start capacitor can be checked by injecting the
normal voltage for a few seconds and than shorting
it. When sparks are generated, the capacitor is in
order.
b. Cover
e. The compressor blades
c. Start capacitor
a2. Start relay
d. Wire hanger