63
The marker is automatically set atop of the carrier peak and the level value is
displayed in the upper right corner of the screen.
Saving and recalling the leakage trace
To save a leakage trace, use the <Save> soft key. Next, press the <Yes> soft key to
confirm selection and the screenshot will be saved into the memory. The traces are
available for downloading using the USB port and the Q-Browser software.
RTN Simple Sweep Generator
RTN Sweep (SSG - Simple Sweep Generator) is
used to generate 64-point Return Path sweep
signals from 5-90 MHz in any desired
configuration and level. A software application
running the Arcom CPD/Sweep Core is integrated
within any PNM platform, and then using standard
MIBs that are part of the RPHY specification the
core requests FFT return data from the CCAP Core
for the desired Remote PHY Node. Upon request
from the user with a Smart Phone connecting to
the Arcom Core, FFT date from the node is
captured, processed by the core, and forwarded to
the technician’s smart phone where sweep result
is viewed instantaneously.
The Quiver-XT also features a receiver that
allows the technician to see local swept responses.