![Arcom Digital Quiver XT Скачать руководство пользователя страница 58](http://html.mh-extra.com/html/arcom-digital/quiver-xt/quiver-xt_user-manual_2964792058.webp)
58
Use the left most soft key to answer Yes and
press <ENTER>. Always make sure you are at the
fiber node. At this point, the Quiver uses all the
parameters you have <Enter>ed (Data Carrier,
Node Number, Output Signal Level) in the
Calibration process. Using the Data Carrier, the
Quiver sends a signal to the headend radar and
waits for a response.
During scanning, while waiting for
confirmation from the headend, you will see the
screen below:
Node Scanning Message
However, if the Data Carrier frequency was set incorrectly, or
if the forward signal connection is bad, or if the forward signal
level is too low (less than -5dBmV) the following error message
appears on the screen:
Содержание Quiver XT
Страница 16: ...16 Node Connection Isolation at Fiber Node ...
Страница 17: ...17 Amplifier Connection Node Connection Isolation at Amplifier ...
Страница 18: ...18 Tap and Splitter Connection Tap and Splitter Connection Isolation at Tap Splitter ...
Страница 44: ...44 ...
Страница 75: ...75 ...