Archon WD2010 Скачать руководство пользователя страница 15

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR 

ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS 

 

 

 

 

Installation: 1004 Rev 4  

Issued: February 7, 2013

 

 

15 

 

 

Figure 5 

Содержание WD2010

Страница 1: ...STRUCTIONS FOR ARCHON MODELS WD2010L WD2010 WD2010H WASHDOWN STATIONS Installation 1004 Rev 4 Issued February 7 2013 1 ARCHON Industries Inc Washdown Stations Models WD2010L WD2010 WD2010H Installatio...

Страница 2: ...tion I INTRODUCTION A Features and Specification The Archon washdown station is a complete pre engineered package including 1 Manually operated valves for steam and water supply lines 2 Diaphragm oper...

Страница 3: ...esign ratings or application data limits Exceeding these limits can cause serious personal injury and or property damage The hot water coming out of the unit may flash to steam if the outlet temperatu...

Страница 4: ...ounding atmosphere in the specific application Important If the performance data of the washdown station as received does not conform with any of the criteria above do not proceed with installation Co...

Страница 5: ...roper sequence 5 After mounting to wall wrench tighten union connections of each manually operated valve Figure 2 B Effect of Related Piping and Precautions 1 The washdown station should be installed...

Страница 6: ...igger of spray gun to establish full flow of water 3 Slowly and partially open the manually operated steam line valve to first check for leaks If leaks are evident close valve allow line to cool off t...

Страница 7: ...are familiar with this equipment and thoroughly understand all the instructions in this manual for all maintenance A Preventive Maintenance Create maintenance schedules safety manuals and inspection d...

Страница 8: ...washdown station out of service and replacing the O Ring or gasket 3 Leaks at the diaphragm should be corrected by tightening the bolts at the diaphragm cap 8 or by taking the unit out of service and...

Страница 9: ...agm and replace it if necessary Do not rotate connector Item 103 Figure 5 after assembling the diaphragm Problem Outlet water temperature is slow in responding to desired temperature Cause Cure Conden...

Страница 10: ...m and water valves 75S 75W c While holding unit firmly to keep it from falling loosen and remove anchor bolts 245 to wall d Remove unit from wall along with pipe spacers 79 and set aside 3 Disassembly...

Страница 11: ...DANGER DANGER O Rings and gaskets are permanently deformed by compression and if reused can cause leaks resulting in the release of live steam This can cause serious personal injury and or property da...

Страница 12: ...d connector 103 onto end of stem assembly 17 by turning in a clockwise direction e Install upper diaphragm casing 45 over the connector 103 and onto the valve body 11 Secure the upper diaphragm casing...

Страница 13: ...0A in the valve body Install O ring 39A on the jet body 82 Ensuring that the two sides line up laterally loosely assemble steam valve body 11 to the jet body 82 with two bolts and nuts 100 4B Do not t...

Страница 14: ...6A Diaphragm Retainer 39A O Ring Flange 125 Wave Washer 39B O Ring Extension 125A Washer 39D O Ring Packing 140 Water Check Spring 39E O Ring Connector 140A Steam Check Spring 39V O Ring Nozzle Jet 14...

Страница 15: ...INSTALLATION OPERATION MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L WD2010 WD2010H WASHDOWN STATIONS Installation 1004 Rev 4 Issued February 7 2013 15 Figure 5...

Отзывы: