OPTIMA PS1 PELLET STOVE
6
6
CAUTION
•
HOT WHILE IN OPERATION.
•
DO NOT TOUCH, KEEP CHILDREN, CLOTHING AND FURNITURE AWAY.
•
CONTACT MAY CAUSE SKIN BURNS. READ NAMEPLATE AND INSTRUCTIONS.
LISTED ROOM HEATER, PELLET FUEL-BURNING TYPE.
ALSO SUITABLE FOR MOBILE HOME INSTALLATION.
MODEL: OPTIMA PS1 FREE STANDING STOVE
TESTED TO: ASTM E1509-04
SERIAL NUMBER / NUMÉRO DE SÉRIE:
DO NOT REMOVE THIS LABEL
MAXIMUM INPUT RATING: 42,000BTU/HR (APPROXIMATELY 5LB/HR OF WOOD PELLETS OR 6LB/HR OF SHELLED CORN)
ELECTICAL RATING: 120VAC, 60HZ, LESS THAN 5A.
THIS APPLIANCE IS SUITABLE FOR MOBILE HOME INSTALLATION IN US & CANADA. SEE MANUAL FOR INSTALLATION
INSTRUCTIONS.
PREVENT HOUSE FIRES
:
INSTALL ONLY IN ACCORDANCE WITH THE MANUFACTURER’S INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL
BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. USE ONLY LISTED TYPE L,
TYPE PL VENT OR OTHER LISTED VENT SYSTEMS SUITABLE FOR PELLET FUEL BURNING STOVE. STRICTLY FOLLOW VENT
MANUFACTURER’S CLEARENCES AND INSTALLATION INSTRUCTIONS. DO NOT CONNECT THIS UNIT TO A CHIMNEY SERVING
ANOTHER APPLIANCE. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. DO NOT CONNECT
THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
UNITED STATES ENVIROMENTAL PROTECTION AGENCY
CERTIFIED TO COMPLY WITH PARTICULATE EMMISION STANDARDS
FOR USE WITH SUITABLE PELLETIZED FUEL ONLY.
See instruction manual on the specifications of fuels.
USE OF OTHER FUELS MAY
DAMAGE THE HEATER AND CREATE A HAZARDOUS CONDITION. DO NOT OBSTRUCT THE COMBUSTION AIR OPENING. RISK OF
SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH ASH CLEAN-OUT SLIDER AND ASH DRAW IN PLACE; AND THE DOOR
FULLY CLOSED. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS AWAY FROM STOVE. DANGER, RISK OF
ELECTRICAL SHOCK, DISCONNECT POWER BEFORE SERVICING STOVE. MOBILE HOME INSTALLATION REQUIRE OUTSIDE
COMBUSTION AIR, PROPER ELECTICAL GROUNDING AND PROPER FASTENING OF STOVE TO THE FLOOR. DO NOT INSTALL IN
SLEEPING ROOM. THE STRUCTUAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALLS AND CEILING/ROOF MUST BE
MAINTAINED.
See manual for instructions. Inspect and clean stove and vent system regularly, see instruction manual for servicing
instructions. Replace glass only with 5mm ceramic glass. Optional Multi-fuel burn pot kit Part # PS1-MF. See manual for other stove options.
Manufactured by: ARCHGARD INDUSTRIES LTD.
MISSION, BC ~ CANADA
Made in Canada
DE
C
NOV
OCT
SEP
AU
G
JUL
JUN
MA
Y
APR
MA
R
FEB
JAN
200
8
DA
T
E
OF MA
NFA
C
T
URE
:
200
7
200
6
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS
RESIDENTIAL & MOBILE HOME INSTALLATION
SIDEWALL
A - 229 mm / 9”
BACKWALL
B - 76 mm / 3”
CORNER
C - 26 mm / 1”
ALCOVE INSTALLATION
SIDEWALL
D - 229 mm / 9”
BACKWALL
E - 76 mm / 3”
MINIMUM ALCOVE CEILING HEIGHT : 1220 mm / 48”
MAXIMUM ALCOVE DEPTH : 915 mm / 36” , Minimum 381 mm /
15” clearance from stove top to ceiling.
6”
6”
6”
FRONT
SIDE
SIDE
FLOOR PROTECTION
Any combustible flooring or floor covering beneath the appliance and / or within the area extending
153mm / 6” horizontally beyond the appliance on any side equipped with a door, and beyond the appliance
on the other sides, shall be protected by a continuous, durable, non-combustible pad that will provide
ember protection. Refer to Canadian CSA B365 and USA NFPA 211 Installation Codes for details. It is
recommended that floor protection extends beneath the vent pipe.
BACKWALL
SIDEWALL
D
E
D
SIDEWALL
A
B
BACKWALL
ADJACENT WALL
SIDEWALL
C
C