5  EXHAUSTS EVACUATION 

 

The pipes for the evacuation of exhausts represent a source of danger, both for fires or the outpour of toxic 
gases. Great caution shall be paid when the exhaust pipe is connected to the flue with walls or parts of them 
made of wood.  
When joining the pipe to the flue, the former shall never overlap into the flue (Figure 4) and the connection 
shall be properly sealed. 
The correct operation of the stove/kitchen is granted exclusively by a good draught of the flue. The minimum 
value to be granted at  

1 meter

 of distance from the exit on the collar of the plate shall be 

> 10 Pa.

  

In case of bad weather conditions (phenomena of thermic inversion), pay particular attention to the emission 
of fumes and gases and to the conditions of the draught.  
In cases of incorrect feeling of the stove/kitchen or lack of air for combustion, the room could fill with smoke 
or unburned gases could come out. In that case, let the fire burn down and check for eventual occlusions in 
the pipes and check the cleanness of the pipes. When the pipes are already partially occluded, the formation 
of deposits on the pipes and into the flue increases rapidly and jeopardizes its optimal function. 
 
 
 

5.1 

POSITIONING AND CONNECTION TO THE FLUE 

 

Per una corretta installazione è fondamentale posizionare la stufa nelle immediate vicinanze di una canna 
fumaria. Il collegamento tra la stufa e la canna fumaria deve risultare il più breve possibile  onde evitare 
fastidiosi  problemi  di  condensa  nelle  tubazioni  e,  comunque,  un  anomalo  funzionamento  della  stufa 
stessa. 
Nel collegamento è buona norma: 
For  a  correct  operation,  the  stove/kitchen  shall  be  installed  in  the  proximity  of  a  flue.  The  connection 
between  stove/kitchen  and  flue  shall  be  as  short  as  possible,  in  order  to  avoid  annoying  problems  of 
condensation in the pipes and, in any case, an anomalous operation of the stove/kitchen itself. 
When performing the connection it is advisable: 

 

Not to exceed with bends (no more than two) (Fig. 5). 

 

Avoid long segments of pipe in horizontal (max 30% of the whole vertical length) (Fig. 5). 

 

Incline the horizontal segments of 10-15% towards the flue to ease the evacuation of the fumes  
(Fig. 5). 

 

Try to have the vertical section of the pipe superior to 1.5 m (Fig. 5). 

    Absolutely avoid that the metal pipe overlaps into the flue (Fig. 3) 

    Properly seal the connection point between pipe and flue 

 

Use, in conformity with the current safety norms, pipes of adequate thickness and with a diameter 
compatible with the collar supplied with the stove/kitchen 

 

5.2 

FLUE AND CHIMNEY POT 

 

The  flue  is  essential  for  a  good  operation  of  any  solid  fuel  heating  device.  The  depression,  commonly 
known as draught, is related to the height of the flue, that shall never be inferior  to 

five meters 

, with a 

section of at least cm. 20x20. It is important that the  flue had no narrowing or air infiltrations, that could 
reduce the correct operation. 
The minimum value of the depression to be granted at 1 meter of distance from the exit of the collar on 
the plate shall be at least 10 Pa. With inferior values, the flame will be weak with formation of soot, bad 
for the pipes, possible exit of smoke from the door when loading wood and very low efficiency. 
It  is  important  that  the  flue  serves  only  one  stove/kitchen. If  several  pipes  should  converge  in  the  same 
flue, the draught will be irregular, with consequences on the good operation of the stove/kitchen. 
If  the  latter  condition  is  compulsory,  the  pipe  shall  be  extended  into  the  flue,  until  a  sufficient  draught 
could be restored (Fig.5). 
A good draught can be checked by igniting a piece of paper at the base of the exhaust pipe. If the draught 
is good, the flame will be attracted with strength towards the inside. 

Caution:

 flues positioned outside the house or in cold environments shall be protected and insulated 

The chimney pot is highly relevant for a good operation of the stove/kitchen, it shall be executed in a way 
that  the  exit  of  the  smoke  shall  take  place  at  least  100  cm  (Fig.4)  higher  than  any  other  structure  in  a 
radius of  10 meters, including the vault of the roof. 
 The surface of the loopholes shall not be inferior to the section of the flue. 

Содержание NONNA AMELIA 300

Страница 1: ...English 1 Rev 09 USE AND INSTALLATION MANUAL WWOD BURNING KITCHEN REGINA 500 AND NONNA AMELIA 300...

Страница 2: ...TS EVACUATION 7 5 1 POSITIONING AND CONNECTION TO THE FLUE 7 5 2 FLUE AND CHIMNEY POT 7 5 3 PROTECTION OF THE FLOOR 10 5 4 SECURITY DISTANCES 10 6 COMBUSTIBLE 11 7 IGNITION 12 7 1 AIR FOR COMBUSTION 1...

Страница 3: ...English 3 Rev 09 11 GENERAL WARRANTY CONDITIONS 20 12 NOTES 22...

Страница 4: ...of wood The main features of the mod REGINA and NONNA AMELIA are Hearth of cast iron built by composed and jointed elements Hearth door with ceramic glass resistant to high temperatures Ash drawer re...

Страница 5: ...e nominal heat output 0 10 Temperature of exhausts C 209 Minimum safety distance from flammable objects mm 200 1 2 DATI TECNICI NONNA AMELIA Height mm 920 Lenght mm 1020 Width mm 670 Weight Kg 230 Dia...

Страница 6: ...stain or support The combustion of fuel releases thermic energy causing a relevant warming of the stove kitchen surface of the doors and of their handles regulation knobs glasses of the exhaust pipes...

Страница 7: ...authorized modifications to the stove kitchen Use only original spare parts recommended by the manufacturer Never use the kitchen with open or half open door Open the door only for adding wood and usi...

Страница 8: ...n two Fig 5 Avoid long segments of pipe in horizontal max 30 of the whole vertical length Fig 5 Incline the horizontal segments of 10 15 towards the flue to ease the evacuation of the fumes Fig 5 Try...

Страница 9: ...English 9 Rev 09 Figura 4 Figura 3 Figura 5...

Страница 10: ...ing of the door and at least 30 cm from the sides of the stove kitchen 5 4 SECURITY DISTANCES 1 From non flammable objects a 200 mm b 100 mm c 400 mm 2 From non flammable objects and concrete bearing...

Страница 11: ...ect use of combustibles could cause the development of toxic substances and damage both the stove kitchen and the flue With a correct combustion process the emitted carbon dioxyde corresponds to the q...

Страница 12: ...hen In order to obtain a quick and correct kindling of the stove kitchen follow accurately the instructions below 1 If the stove kitchen and the flue are cold or the atmospheric pressure is low burn a...

Страница 13: ...primary air 1 hearth grid lever 2 and kindling valve 4 closed secondary air 3 open by half 3 41 kg of wood burned in 1 hour length between 20 25 cm and draught of the chimney flue equal to 12Pa In ord...

Страница 14: ...clean the ceramic glass of the hearth door and the eventual protection glass The excess of soot on the ceramic glass of the hearth indicates a lack of draught of the flue that could in some cases be...

Страница 15: ...t edge 10 Reassemble the connection pipe to the flue 8 4 CLEANING OF THE GLASS AND OF THE HEARTH DOOR The best way to clean the glass of the hearth door is to use a wet cloth Persistent dirt can be re...

Страница 16: ...r wood with humidity inferior to 15 The stove kitchen does not operate in a regular way Insufficient draught of the flue Check the draught Soot deposits on the inside of the stove kitchen Follow the c...

Страница 17: ...ven door washer 09 Cooking plate frame 45 Glass washer 10 Ash drawer 46 Oven door handle 11 Wood stopper 47 Oven door glass 12 Hearth door glass 48 Oven thermometer 13 Hearth door 52 Protection glass...

Страница 18: ...English 18 Rev 09 Figure 11...

Страница 19: ...English 19 Rev 09 Figure 12...

Страница 20: ...IDITY The warranty is acknowledged as valid provided that The stove is installed according to current regulations on the subject adhering to the instructions contained herein and by a professionally s...

Страница 21: ...n adequate anti condensation circuit is not made and the specifications for correctly doing so contained herein are not followed idro products Any calibration or adjustments of the product in relation...

Страница 22: ..._____________________________________________________________________ ______________________________________________________________________________________ ___________________________________________...

Страница 23: ...English 23 Rev 09 Arce Stufe srl via Primo Maggio 14 12025 Dronero CN Italia Tel 0171 425511 Fax 0171 425560 http www arcestufe eu e mail arce arcestufe eu...

Отзывы: