![Arce NONNA AMELIA 300 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/arce/nonna-amelia-300/nonna-amelia-300_use-and-installation-manual_2963855016.webp)
English
16
Rev.09
9 PROBLEM SOLVING GRID
Problem
Cause
Solution
Soot covers the glass too quickly
Insufficient draught
Either clean the flue or make it longer
Incorrect regulation of the air intake
Regulate the air intake according to
the instructions of the manual. For
long periods at the minimum, the glass
dirties itself more rapidly but part of
the soot burns and is removed once a
correct regulation reached.
Humid wood
Use, as alternative, pressed wood logs
or wood with humidity inferior to 15%
The stove/kitchen does not operate in
a regular way
Insufficient draught of the flue
Check the draught
Soot deposits on the inside of the
stove/kitchen
Follow the cleaning indications of the
manual
The combustible does not burn in a
regular way
Unfavourable weather conditions
Insufficient draught of the flue
Check the draught
Wrongful kindling process
Check the “ignition” paragraph
The stove/kitchen emits smoke
The stove/kitchen is dirty
Follow the cleaning indications of the
manual
Smoke output when adding wood
Insufficient draught of the flue, the
exhaust is not tight
Check the connections, the joints and
the cleanness
Содержание NONNA AMELIA 300
Страница 1: ...English 1 Rev 09 USE AND INSTALLATION MANUAL WWOD BURNING KITCHEN REGINA 500 AND NONNA AMELIA 300...
Страница 3: ...English 3 Rev 09 11 GENERAL WARRANTY CONDITIONS 20 12 NOTES 22...
Страница 9: ...English 9 Rev 09 Figura 4 Figura 3 Figura 5...
Страница 18: ...English 18 Rev 09 Figure 11...
Страница 19: ...English 19 Rev 09 Figure 12...