9.1 Mounting 

1.  Lay out the tools, lifting aids, screws, nuts and seals that you need to 

install the visual level indicator. 

2.  Position the visual level indicator on the tank. When doing so, make 

sure that the TOP sticker on the indication rail is pointing upwards. 

3.  If needed, add seals to the connection threads or between the flange 

connections. 

-

 Flange 

connections 

Tighten the flange connection screws diagonally. Check that the 
screw connections are a tight fit. 

-

 Weld 

sockets 

Remember that heat will be built up when welding weld sockets. 
Components at risk should be covered, cooled, or temporarily 
removed. 

-

 Screw-in 

threads 

The visual level indicator and indication rail must not be used to 
provide counter torque when installing the screw-in threads. Use a 
suitable tool for counteraction without putting stress on or damaging 
mounted parts. 

 

9.2 Inspecting 

For all types of installation, make sure that the process connections for the 
visual level indicator are aligned with the tank’s process connections. 
 
The visual level indicator must be installed in a vertical position. You can 
check this with a spirit level on the float chamber. Deviations of up to 5° from 
the vertical position are acceptable. Larger deviations may result in increased 
friction on the float in the float chamber and may lead to blockages. It is 
imperative that this is agreed with the supplier. 
 
Twisting or bending of the float chamber, caused by incorrect socket 
distances for example, may block the float and lead to the visual level 
indicator breaking down! 
 

10. Commissioning 

Installation (point 8 to point 9) must be fully completed before commissioning.

 

 

  If the data marked on the type plate (density, max. operating pressure, max. operating 

temperature, connection dimensions, material, etc.), does not match the application, the visual 
level indicator may display an incorrect level, and it may be damaged and pose a risk to people 
and the environment. Make sure that the data marked on the type plate matches the application. 

  Check the visual level indicator for visible external damage before use. Do not put a damaged 

visual level indicator into operation. 

   The visual level indicator may only be used for the purposes recorded on the type plate and the 

Ex label. 

 

 

Содержание 23013

Страница 1: ...Installation and Operating Manual Visual Level Indicator VLI Date 17 03 2020 Version E 10 1...

Страница 2: ...WEKA_IOM_VLI_EN 17 03 2020 1 31 Notes Order Date...

Страница 3: ...2 Cleaning visual level indicator 16 12 1 Cleaning the outside 16 12 2 Cleaning the float chamber and the float 16 12 3 Cleaning the float chamber and float for a top of tank assembly 17 13 Operating...

Страница 4: ...1 HighPressure Power 250 26431 HighPressure Power 315 38400 HighPressure Power 400 38500 HighPressure Power 500 39020 PetroLine 20 39021 PetroLine 20 low density 39050 PetroLine 50 39051 PetroLine 50...

Страница 5: ...re Equipment Directive 2014 68 EU When opening the visual level indicator bear in mind that the fluids and gases it contains could be hazardous to health It is imperative that you comply with the safe...

Страница 6: ...for fluids The visual level indicator may only be used for the purposes recorded on the type plate The information noted down on the type plate and data sheet must conform with ideal plant operating...

Страница 7: ...standpipe 6 Float 7 Indication rail see below for details 8 Type plate with customer specific parameters 9 Top sticker 10 Service connections top and bottom Process and service connections may be Fla...

Страница 8: ...cess connections top and bottom 31 Top service flange plug 32 Possible ventilation hole with plug 33 Bottom service flange plug 34 Possible drain hole with plug 5 2 Top of tank design Figure 4 2 40 Fl...

Страница 9: ...ription The fluid level in the float chamber corresponds to the fluid level in the tank communicating vessels The bar magnet has been integrated into the float in a way that means the centre of the ba...

Страница 10: ...for assembly 8 1 Unpacking 1 Lay the visual level indicator and the packaging flat on the floor 2 Remove the packing tape 3 Remove the staples in the overlapping cardboard at both ends of the packagi...

Страница 11: ...he functioning of the visual level indicator Remove them completely An incorrectly installed float will lead to the incorrect fill level being displayed Slide the float into the float chamber as shown...

Страница 12: ...e bottom service flange plug If you re dealing with a flange tighten the screws diagonally Bear any tightening torque information in mind VLI line VLI type Torque Nm SmartLine 34000 20 34110 StandarLl...

Страница 13: ...float is in the float chamber and is stopped from moving around thanks to a screw at the bottom end of the chamber 3 Type 23013 Remove cable tie and dispose properly Type 25270 Turn the screw until th...

Страница 14: ...mperature before working on the visual level indicator Wear suitable protective equipment gloves face guard possibly breathing apparatus The visual level indicator may only be used for the purposes re...

Страница 15: ...nections The visual level indicator must be installed in a vertical position You can check this with a spirit level on the float chamber Deviations of up to 5 from the vertical position are acceptable...

Страница 16: ...cator if it is working properly Do not use an unsealed visual level indicator Working on hot or pressurised visual level indicators may result in physical injuries burns chemical burns or poisoning De...

Страница 17: ...ure carry pressure related risks Depressurise the tank before working on the visual level indicator and observe the information of the local valid pressure regulations i e Pressure Equipment Directive...

Страница 18: ...ear suitable protective equipment gloves face guard possibly breathing apparatus Keep a sufficient distance away while the machine is in operation Visual level indicators run at excessive pressure car...

Страница 19: ...al level indicator or its packaging To avoid damage in transit secure the flat with a safety device Store the visual level indicator in a dry environment Avoid contact with water and moisture Temperat...

Страница 20: ...ack the float in separate packaging 15 2 Disposing of the visual level indicator Protect the environment and take the visual level indicator to be disposed of properly 16 Troubleshooting Problem Possi...

Страница 21: ...cessary 17 Label 17 1 Type plate The visual level indicator may only be used for the purposes recorded on the type plate The information noted down on the type plate and data sheet must conform with i...

Страница 22: ...WEKA_IOM_VLI_EN 17 03 2020 21 31 19 EU Declaration of Conformity for non explosion proof devices...

Страница 23: ...WEKA_IOM_VLI_EN 17 03 2020 22 31 20 EU Declaration of Conformity for explosion proof devices...

Страница 24: ...WEKA_IOM_VLI_EN 17 03 2020 23 31 21 ATEX Certificate Type Examination Certificate...

Страница 25: ...WEKA_IOM_VLI_EN 17 03 2020 24 31...

Страница 26: ...WEKA_IOM_VLI_EN 17 03 2020 25 31...

Страница 27: ...WEKA_IOM_VLI_EN 17 03 2020 26 31 22 IECEx Certificate of Conformity CoC...

Страница 28: ...WEKA_IOM_VLI_EN 17 03 2020 27 31...

Страница 29: ...WEKA_IOM_VLI_EN 17 03 2020 28 31...

Страница 30: ...WEKA_IOM_VLI_EN 17 03 2020 29 31...

Страница 31: ...WEKA_IOM_VLI_EN 17 03 2020 30 31...

Отзывы: