![ARC Flex 2JX Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/arc/flex-2jx/flex-2jx_user-manual_2963278037.webp)
Page 36
SW4 RLY
>S
SW4 RLY
SW4 RLY
>BACK
NORMAL
NORMAL
>NORMAL
>TOGGLE&E
>STOP
>PITCH&E
>SW5 RLY
>PITCH
>SW4 RLY
>NORMAL
>SW4 RLY
NORMAL
SW4 RLY
>TOGGLE
NORMAL
4.2.18 SW4 Output Relay Function
PS1 button is the “Enter” or “Change” command.
PS2 button is the “Next” command.
Select “NORMAL” the output relay becomes momentary contact.
Select “S” the output relay becomes momentary contact. Must press the green
START button together to work.
Select “TOGGLE” the output relay becomes toggled contact.
Select “TOGGLE&E” the output relay becomes toggled contact affected by the e-stop
command (output relay opens when e-stop button is pressed).
Select “PITCH” SW4 button becomes the “Pitch” function in Pitch & Catch Operation.
Select “PITCH&E” SW4 button becomes the “Pitch” function in Pitch & Catch Operation.
When Pitch command is initiated the receiver mains are disconnected.
Select “STOP” SW4 button becomes an auxiliary e-stop function. Press to disconnect the
receiver mains and press START button to reconnect the receiver mains.
When select Pitch & Catch function make sure you set the spare transmitter to the next
channel up and the receiver channel scanning to “02” (see section 4.2.4).
Important note:
When one of the above is selected make sure the same SW4 button
function on transmitter is set to “NORMAL” (see section 4.1.13).
Содержание Flex 2JX