Switch Placement
2.2.1
—
General Guidelines
This section describes proper placement and mounting for the AN-100-SW-R network
switch, including shelf, rack, and on-wall installation.
Note:
Section 2.2.1 applies to all AN-100-SW-R models. Section 2.2.2 addresses all
placement options for the AN-100-SW-R-5 port switch. Section 2.2.3 covers all placement
options for the AN-100-SW-R 8/ -16,/ -24 models.
Consider the following guidelines before choosing any location or mounting type for
the switch:
Do not deploy the device in a location where any of the following conditions exist:
•
Make sure that the switch is accessible and that the cables can be connected with ease.
Using cable management accessories is highly recommended for rack installations.
•
Keep cabling away from sources of electrical noise, power lines, and fluorescent
lighting
fixtures.
•
Keep the switch away from water and moisture sources.
•
Power the device from an outlet with adequate capacity. Plugging in the switch must
not
overload the circuit in use.
•
The use of a power conditioner or surge protector is highly recommended for all
attached
network equipment. A surge at one piece of unprotected equipment could pass through
the network cable and damage other devices, even if they are protected.
•
High Temperature:
The ambient temperature must not exceed 104°F (40°C).
•
Low Air Flow:
Both side panels must be unobstructed to prevent overheating. Leave
3 inches of open air space on all sides of the network switch. Avoid covering any
ventilation holes.
•
Mechanical Instability:
The device should be level, stable, and secure to avoid it sliding
or shifting out of position. The included rubber feet will help prevent unwanted movement
for shelf-mounted switches. Do not mount the switch to any rack or wall that is unstable
or damaged.