5 MAINTENANCE
- After every spraying operation, flush the pipe with clean water.
- In case of malfunction, and at any rate at the end of every season, clean the flowmeter pipe with
a special detergent.
- Do not use metal or abrasive objects for cleaning the duct.
- Do not use solvents or petrol for cleaning the external parts of the device.
5.1 Troubleshooting
FAULT
CAUSE
REMEDY
The flowmeter does not read any
value
No power supply
• Check the flowmeter wiring.
The value read by the flowmeter is
not linear or stable
Presence of turbulence or air in the
circuit
• Check the circuit
.
Tab. 4
6
TECHNICAL DATA
Description
Orion
Power supply
11 ÷ 14,5 Vdc
Max. absorption
300 mA
Min. liquid conductivity
50 µS/cm
Working temperature
0 °C ÷ 60 °C
+32 °F ÷ +140 °F
Storage temperature
-20 °C ÷ 60 °C
-4 °F ÷ +140 °F
Dimensions (mm)
100x200x126 / 105x114x126 (depending on the type)
Weight
886 ÷ 1650 g (depending on the type)
Tab. 5