background image

3

IMMAGINI - IMAGES - IMÁGENES - IMAGENS

 Fig. I 

1

2

3

4

5

 Fig. II  

2 vie

2 ways

2 vias

2 vías

 Fig. III

3 vie - attacco laterale

3 ways - side connection

3 vias - conexión lateral

3 vías - engate lateral

 Fig. IV

3 vie - attacco inferiore

3 ways - bottom connection

3 vias - conexión inferior

3 vías - engate por baixo

 Fig. V 

*Non presente su tutti i modelli

*Not present on all models

*No presente en todos los modelos

*Não existe em todos os modelos

2

1*

 Fig. VI 

Collegamento a 3 fili

3-wire connection

Conexión a 3 cables

Conexão de 3 fios

 Fig. VII 

Collegamento a 2 fili

2-wire connection

Conexión a 2 cables

Conexão de 2 fios

 Fig. VIII 

Содержание 8537 Series

Страница 1: ...A A SFERA ELETTRICA ELECTRIC BALL VALVE V LVULA EL CTRICA DE BOLA V LVULA DE ESFERA EL TRICA INSTALLAZIONE USO E MANUTENZIONE INSTALLATION USE AND MAINTENANCE INSTALACI N USO Y MANTENIMIENTO INSTALA O...

Страница 2: ...1 1 4 12 8537x 5xxx 2 3 sec 3 way bottom connection only 4 6 sec 40 1 1 2 12 5 25 49 5 20 93 52 192 40 49 4 36 8537x 6xxx 50 T7 43 118 61 210 57 60 5 44 2 16 28 55 26 8537x 7xxx 65 2 1 2 16 35 136 71...

Страница 3: ...acco inferiore 3 ways bottom connection 3 vias conexi n inferior 3 v as engate por baixo Fig V Non presente su tutti i modelli Not present on all models No presente en todos los modelos N o existe em...

Страница 4: ...rsonale preparato e fatte a circuito non in pressione e senza alimentazione elettrica connettore scollegato ARAG NON RISPONDE PER DANNI DI QUALSIASI NATURA CAUSATI DA UN INSTALLAZIONE ESEGUITA DA PERS...

Страница 5: ...eguito e terminato correttamente le connessioni idrauliche AZIONARE LA VALVOLA CON UNA O PI ENTRATE USCITE APERTE MOLTO PERICOLOSO E PU CAUSARE INCIDENTI E GRAVI LESIONI ALL INSTALLATORE O MANUTENTORE...

Страница 6: ...filetti possibile rinforzare la tenuta utilizzando esclusivamente nastro in PTFE non sinterizzato ATTENZIONE Per conoscere la massima pressione di utilizzo relativa alla connessione scelta fate riferi...

Страница 7: ...no essere stretti utilizzando una chiave dinamometrica tarata secondo quanto riportato in Tab 1 Ricollegate tutte le connessioni idrauliche Ricollegate la connessione elettrica Mettete in pressione l...

Страница 8: ...ied out by qualified personnel with circuit not under pressure and without power supply connector disconnected ARAG IS NOT LIABLE FOR ANY DAMAGE RESULTING FROM INSTALLATION BY UNSKILLED PERSONNEL ANY...

Страница 9: ...completed the hydraulic connections OPERATING THE VALVE WITH ONE OR MORE INLETS OUTLETS OPEN IS VERY DANGEROUS AND CAN CAUSE ACCIDENTS AND SERIOUS INJURIES TO THE INSTALLATION OR MAINTENANCE PERSONNEL...

Страница 10: ...f for any reason the pipes leak at connection points apply unsintered PTFE tape to improve sealing CAUTION For the maximum operating pressure for the chosen connection refer to Tab 2 Tab 3 Once all th...

Страница 11: ...a dynamometric spanner calibrated according to that which is indicated in Tab 1 Reconnect all the hydraulic connections Restore electric power supply Put the system under pressure ONLYWITH CLEANWATER...

Страница 12: ...ctuadas por personal preparado y realizadas con el circuito que no se encuentra bajo presi n y sin alimentaci n el ctrica conector desconectado ARAG NO RESPONDE POR DA OS DE CUALQUIER TIPO DEBIDO A LA...

Страница 13: ...ado correctamente las conexiones hidr ulicas ACCIONAR LA V LVULA CON UNA O VARIAS ENTRADAS SALIDAS ABIERTAS ES MUY PELIGROSO Y PUEDE PROVOCAR ACCIDENTES Y GRAVES HERIDAS AL INSTALADOR O LA PERSONA ENC...

Страница 14: ...roscadas Si por cualquier motivo se verificaran p rdidas en las roscas podr reforzarse la estanqueidad utilizando exclusivamente cinta de PTFE no sinterizada ATENCI N Para conocer la m xima presi n d...

Страница 15: ...apretarse utilizando una llave dinamom trica calibrada seg n lo indicado en Tab 1 Volver a efectuar todas las conexiones hidr ulicas Volver a efectuar la conexi n el ctrica Poner la instalaci n bajo...

Страница 16: ...das e feitas quando o circuito n o estiver em press o e sem alimenta o el trica conector desligado A ARAG N O RESPONDE POR DANOS DE QUALQUER NATUREZA CAUSADOS POR UMA INSTALA O FEITA POR PESSOAL SEM E...

Страница 17: ...corretamente as conex es hidr ulicas ACIONAR A V LVULA COM UMA OU MAIS ENTRADAS SA DAS ABERTAS MUITO PERIGOSO E PODE PROVOCAR INCIDENTES E GRAVES FERIDAS AO INSTALADOR OU T CNICO DE MANUTEN O N O INTR...

Страница 18: ...squeadas Se por qualquer motivo ocorressem perdas pelas roscas poss vel refor ar a veda o utilizando exclusivamente fita de PTFE n o sinterizada ATEN O Para ter conhecimento da press o m xima de servi...

Страница 19: ...adas utilizando para isso uma chave dinamom trica calibrada de acordo com o que foi citado na Tab 1 Conecte novamente todas as conex es hidr ulicas Conecte novamente a conex o el trica Coloque em pres...

Страница 20: ...integrante del equipo al cual hace referencia y debe acompa arlo siempre tambi n en caso de venta o cesi n Conservarlo para cualquier referencia futura ARAG se reserva el derecho a modificar las espe...